Maintenance
64
TOX_Manual_Powerpackage_line-Q_en
10.5
Lowering of oil level
CAUTION
Environmental pollution caused by environmentally harmful liquids!
è
Absorb spilled liquids and remove without residue.
è
Dispose of liquid according to the statutory regulations.
NOTE
Damage to seal due to high oil level!
After refilling and venting, lower the oil level by a defined value (lowering
volume "ΔV").
For lowering volume "ΔV" see type plate.
Material required:
Oil pump ZP 20
ü
System is in maintenance position.
See
Set system to maintenance position, Page 59
ü
Drive is filled and vented.
See
Refilling oil and venting drive, Page 61
1.
Remove venting plate with locking wire.
2.
Unscrew knurled cap of the oil filling nipple.
3.
Screw filling hose of the oil pump onto oil filling nipple.
4.
CAUTION!
Risk of slipping from leaking oil! Absorb oil immediately and
without residue!
Remove oil quantity exactly according to lowering volume "ΔV".
5.
Unscrew filling hose of the oil pump.
6.
Install venting plate.
7.
Screw on knurled cap of the oil filling nipple.
8.
Fasten locking wire.
9.
Push in oil level indicator needle.
Summary of Contents for Powerpackage Q Series
Page 2: ...2 TOX_Manual_Powerpackage_line Q_en ...
Page 24: ...Technical data 24 TOX_Manual_Powerpackage_line Q_en ...
Page 54: ...Troubleshooting 54 TOX_Manual_Powerpackage_line Q_en ...
Page 56: ...Maintenance table of Powerpackage 56 TOX_Manual_Powerpackage_line Q_en ...
Page 66: ...Maintenance 66 TOX_Manual_Powerpackage_line Q_en ...
Page 68: ...Repairs 68 TOX_Manual_Powerpackage_line Q_en ...
Page 72: ...Disassembly and Disposal 72 TOX_Manual_Powerpackage_line Q_en ...
Page 74: ...Appendices 74 TOX_Manual_Powerpackage_line Q_en ...
Page 75: ......
Page 76: ......