Technical data
TOX_Manual_FinePress_PFHL-PFHW_en
23
4 Technical data
4.1
Type sheet and data sheet
For technical data and installation dimensions see type sheet and data.
(
https://www.tox-pressotechnik.com
4.2
Compressed air quality and pneumatic connection
The following is required:
Filtered and dried compressed air
Lightly oiled compressed air is permitted.
Compressed air quality (according to DIN ISO 8573-1):
Solids
Water dew point
Maximum Oil content
Class
[μm]
Class
[°C]
Class
[mg/m3]
5
40
4
3
3
1
4.3
Compressed air press force table
Air pres-
sure [bar]
PFHx 008
Force F
[kN]
PFHx 013
Force F
[kN]
PFHx 022
Force F
[kN]
PFHx 033
Force F
[kN]
PFHx 056
Force F
[kN]
2
2.9
4.4
7.5
11.4
19.0
2.5
3.6
5.4
9.1
14.2
23.5
3
4.4
6.6
11.0
17.1
28.4
3.5
5.2
7.7
13.1
19.9
33.1
4
5.9
8.8
15.2
23.0
38.0
4.5
6.7
10.0
17.1
25.7
42.9
5
7.4
11.1
19.2
28.8
47.6
5.5
8.2
12.2
21.2
31.6
52.4
6
8.9
13.4
23.0
34.4
57.4
Tolerance of the technical specifications ±5%.
Summary of Contents for FinePress PFHL
Page 2: ...2 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 12: ...Important information 12 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 22: ...About this product 22 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 24: ...Technical data 24 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 44: ...Installation 44 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 46: ...Commissioning 46 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 54: ...Operation 54 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 58: ...Maintenance table 58 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 66: ...Repairs 66 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 70: ...Disassembly and Disposal 70 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 71: ...Appendices TOX_Manual_FinePress_PFHL PFHW_en 71 13 Appendices 13 1 Declaration of conformity ...
Page 72: ...Appendices 72 TOX_Manual_FinePress_PFHL PFHW_en ...
Page 73: ......
Page 74: ......