Software
72
TOX_Manual_Process-monitoring-unit_CEP400T_en
Button, input/control panel
Function
10
Calibrating
The force sensor calibration menu opens.
11
Offset adjustment
Read in the current measuring signal as
offset of the force sensor.
Setting the nominal force of the force sensor
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
The ''Configuration -> Force sensor configuration '' menu is opened.
1.
Tap on the
Nominal force
input field.
w
The numerical keyboard opens.
2.
Enter the value for the desired nominal force and confirm with
↲
.
3.
If necessary: Tap on the
Nominal force, unit
input field.
w
The alphanumeric keyboard opens.
4.
Enter the value for the desired unit of the nominal force and confirm
with
↲
.
Adjusting the offset force sensor
The
Offset
parameter adjusts a possible zero point offset of the analog
measurement sensor of the sensor.
An offset adjustment must be carried out:
once a day or after approx. 1000 measurements.
when a sensor has been changed.
Adjustment using Offset adjustment button
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
The ''Configuration -> Force sensor configuration '' menu is opened.
ü
Sensor is load-free during the offset adjustment.
è
Tap on
Offset adjustment
button.
w
The current measurement signal (V) is applied as offset.
Summary of Contents for CEP400T
Page 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Page 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 117: ......
Page 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Page 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...