Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
69
Setting measuring cycles
F
max
F
soll
F
warn
F
min
F
warn
F
warn
= F
max
-
100%
F
max
- F
soll
*
F
warn
= F
max
+
100%
F
max
- F
soll
*
Warning limit %
Warning limit %
When the warning limit is activated the warning limit counter is raised by
value '1' after every violation of the lower and upper warning limit. As soon
as the counter reaches the value set in menu item
Measuring cycles
the
signal 'Warning limit reached' is set for the relevant channel. After each fur-
ther measurement the yellow symbol Warning limit message is displayed.
The counter is automatically reset when a further measuring result lies
within the set warning limit window. The counter is also reset after a restart
of the device.
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
1.
Tap on the
Measuring cycles
input field.
w
The numerical keyboard opens.
2.
Enter a value between 0 and 100 and confirm with
↲
.
Configuring the force sensor
In menu ''Configuration -> Configuration of force sensor'' the parameters of
the force sensor are specified for the active process.
è
Open the ''Configuration -> Force sensor configuration'' by tapping the
button
in ''Configuration''.
Summary of Contents for CEP400T
Page 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Page 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 117: ......
Page 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Page 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...