background image

TC30 
COUNTRY HOME
BURNER KIT 
INSTRUCTIONS

(NATURAL GAS ONLY)

PART#

TC30.NG02DN
For TC30 Series D
Fireplaces

020317-16 

        

     TC30_NG02DN         5056.42902D

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

These instructions are supplementary to the Installation and 
Operating Instructions supplied with the fireplace and should be 
kept together. Refer to the Installation and Operating Instructions for 
proper gas supply, safety requirements and operating instructions

Visit www. townandcountryfireplaces.net for the most recent version of this manual

Summary of Contents for TC30.NG02DN

Page 1: ...e CONSUMER Retain this manual for future reference These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kepttogether RefertotheInstallationandOperatingInstructionsfor proper gas supply safety requirements and operating instructions Visit www townandcountryfireplaces net for the most recent version of this manual ...

Page 2: ... Log Grate Figure 1 TC30_NG02DN Kit contents 2 TC30_NG02DN 020317 16 5056 42902D Contents of Package Burner Grate Installation 1 Place the keyhole slots of the burner Figure 3 over the two screws located on the firebox floor Figure 2 Screws Figure 2 Firebox base ...

Page 3: ...rt of the keyhole slot and tighten screws Figure 4 3 Remove access cover to the vavle control center from right side of firebox Figure 5 Figure 3 Burner assembly over top of right side screw Figure 4 Burner assembly pushed back against right side screw Figure 5 Access cover to valve control center ...

Page 4: ...connections are gas tight Interface module Figure 6 Gas and pilot supply tubes Interface module Bulkhead plate Ignition and sensor wires Figure 7 Ignition and sensor wires routing 5 Feed the ignition and sensor wires through the bulkhead plate to the interface module Tuck the ignition and sensor wires below the supply tubes Figure 7 ...

Page 5: ...stalled See Installation and Operating Instructions manual for details 6 Attach the ignition and sensor wires to the Interface module as shown in Figure 8 7 Reinstall the valve control center access panel See Figure 5 on page 3 Ignition wire red Flame sensor wire white Interface module Figure 8 Interface module ...

Page 6: ... the log grate securing brackets over the holes in the floor shield and secure with the two screws Figure 9 9 Attach rear deflector to rear of grate using the two screws provided Figure 10 Figure 9 Securing log grate to the floor Air deflector securing screws Figure 10 Rear air deflector ...

Page 7: ...ompress leave it loose for best performance Fill the burner pan level with the top of the pan at rear and gradually slope forward to the firebox floor at the front covering both burner tubes Place remaining ember material outside of the burner pan as desired to cover up gas lines and brackets Note Ember material placement and amount will affect flame appearance More ember material results in lower...

Page 8: ...y the following pictures The three main logs have holes and or pins Engage each pin in the corresponding holes The four smaller logs do not have holes or pins They rest in position Locate as per the diagrams 12 through 19 Log Placement 1 Figure 12 First log placement 2 Figure 13 2nd log placement Note Improper placement of logs will cause sooting on internal parts and glass The logs may need to be...

Page 9: ...9 TC30_NG02DN 020317 16 5056 42902D 3 Figure 14 3rd log placement 4 Figure 15 4th log placement ...

Page 10: ...10 TC30_NG02DN 020317 16 5056 42902D 5 Figure 16 5th log placement 6 Figure 17 6th log placement ...

Page 11: ...11 TC30_NG02DN 020317 16 5056 42902D 7 Figure 18 7th log placement 3 2 1 5 6 7 4 Figure 19 Completed log placement ...

Page 12: ...ure test port Verify gas pressures with the fireplace lit and on the highest setting 1 Remove the blanking plug from the pressure test port The plug is located between the right side lintel and firebox side Figure 20 2 Thread the extension test fitting into the open test port Figure 21 3 Attach a pressure gauge onto the fitting 4 When testing is complete remove the extension test fitting and repla...

Page 13: ...to enhance the ember material glow and lessen the flame height Burner Flame Adjustment Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass To Adjust 1 Open and remove window frame and set aside See Window Frame Removal section found in the Installation and Operating Instructions manual 2 Remove t...

Page 14: ...Y 1d PILOT SHIELD 1e BLOCKER PLATE 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET 1i HEAT SHIELD 1j HEAT SHIELD INSULATION KIT CONTENTS WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION Replacement Parts ITEM DESCRIPTION PART NO ITEM DESCRIPTION PART NO 4 PILOT ASSEMBLY CONVERTIBLE TCRP 5005025 5 MAIN SUPPLY TUBE 5019 223 6 PILOT TUBE 5019 225 2 7 PCS LOG SET 3 ORIFICE NATURAL GA...

Page 15: ...15 TC30_NG02DN 020317 16 5056 42902D ...

Page 16: ...w townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws ...

Reviews: