- 4 -
tousek
/ EN_ST-12-5_05 / 25. 03. 2020
Text display
–
ESC
ENTER
+
K
FE
F1
SV
ZM
30 31 30 32 34 50 52 53
72 73 41 42 43 44 45 46 48
20 21 24 25
0
1
2
10 11 5 6
LPA
F2
Control board features
1. General features
Swing gate control unit ST 12/5
• suitable for 1/2 leafed swing gates with gate automation
SLIM-SLR and SLIM-CLR (with integrated limit switches)
• adjustable leaf delay
• ARS (Autom. reversal system - obstacle detection)
• automatic closure with adjustable pause time.
• Additional function for permanent open
• separately adjustable softstop time of both operators
• adjustable force
• Operating mode: impulse-, automatic- or deadman mode
• partial opening for pedestrians (pedestrian function)
• direct connection for 8,2 kOhm safety edges (2-channel)
• self-monitoring of photocells
• self-diagnosis
• electric lock output
• slot for optional radio receiver and additional moudle for gate
status or for courtyard lamp/control lamp
• easy programming thanks to text display
• optional: emergency mode with battery
Technichal data
Swing gate control board ST 12/5
Power supply
230V a.c., +/-10% 50Hz
Ambient temperature
- 20°C bis + 50°C
Motor output
2 x 12V DC, 60W
Protection class
IP54
Flashing light output
230V AC, 50W max.
Battery (optional)
Bleigelakku 12V 2,1Ah
Electric lock output
12V DC, 15W
Art.Num.
12111730
Photocell output
12V DC, 2W
Optional components
pluggable receiver • backup battery • add. module for courtyard/control lamp or gate status
Components of the control board
(K)
terminal blocks
(SV)
service slot (e.g. for software update) or connection
with optional tousek-service-interface (TSI)
(FE)
slot for optional radio receiver (
p. 21)
(ZM)
slot for optional additional module (
p. 19)
(LPA)
loading board connection for optional emergency battery
(T)
transformer
(F1)
primary fuse T 2A
(F2)
secondary fuse T 10A
Text display and programming keys +, -, ESC and ENTER
Attention
During connection, adjustment and main-
tenance works please take care, that the
electronic circuit board won´t be damaged by
moisture (rain).
Control board overview
Important
The optional tousek-
service-interface must be
connected with socket
(SV)
!
230V
a.c.
T
12V
a.c.