Page 1: ...erica 800 368 9700 International 1 714 632 7100 1321 S State College Blvd Fullerton CA 92831 USA Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids PFDM2 ...

Page 2: ... kg x4 M4 x 12mm screw x4 M4 x 16mm screw x4 M4 x 25mm screw x4 M6 x 12mm screw x4 M6 x 16mm screw x4 M6 x 25mm screw x4 M8 x 16mm screw x4 M8 x 25mm screw x4 5 16 x 3 Lag Bolts x4 Washers x4 Universal 3 HoleWasher x8 Universal Spacer x1 Depth Measuring Straw x1 Lock it Barrel Page 2 Pencil Level 1 4 Drill Bit for Wood Stud Electronic Stud Finder Socket Wrench Phillips Tip Screwdriver Tape Measure...

Page 3: ...es which edge is the top Mounting Safety Two people are recommended for the installation of this mount www mounts com North America 800 368 9700 International 1 714 632 7100 X X You must secure the wall plate to two 2 wall studs with a minimum of four 4 lag bolts 2 lag bolts for each stud found n n Use a stud finder to determine the exact center of wall studs in the vicinity of the wall plate o o ...

Page 4: ... another person to mark the wall stud location n n Place the wall plate against the wall in the desired viewing location o o Adjust the wall plate to align the mount slots in the wall plate with the center of the wall studs p p Level the wall plate q q Use a pencil to mark the upper right mounting location along the center of the wall stud Drill a pilot hole in the center of the upper right mark u...

Page 5: ...cket wrench and 1 2 socket Do not overtighten the lag bolt 5 www mounts com North America 800 368 9700 International 1 714 632 7100 Page 5 n n Level the wall plate o o Use a pencil to mark the remaining three 3 mounting locations along the center of each wall stud PFDM2 Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids ...

Page 6: ...use 1 4 drill bit when drilling the pilot holes n n Insert one 1 5 16 x 3 lag bolt and one 1 5 16 washer into each pilot hole o o Tighten all lag bolts using a socket wrench and 1 2 socket Do not overtighten the lag bolts when attaching the mount to the wall Improper installation may result in personal injury or property damage Proceed to the Installing the Mounting Bracket section Installation Gu...

Page 7: ...t the small straw or toothpick into the remaining threaded inserts to compare and verify their depth using the straw or toothpick s 1 8 allowance mark r r Locate the correct diameter screw for the threaded insert If the screw you selected is longer than the 1 8 allowance mark on the small straw or toothpick as shown in Figure 2 and Figure 3 do not use this screw The screw length must not bypass th...

Page 8: ...Spacers Remove the mounting brackets Universal Washers and mounting screws from the back of the flat panel Proceed to the Universal Spacer Installation section If No skip to the Attaching the Mounting Bracket to the Flat Panel section Premier Mounts Universal Spacers allow you to attach the mounting bracket to flat panels which have recessed or uneven mount points Each Universal Spacer adds to the...

Page 9: ...ng screw any further will prevent you from safely attaching the flat panel to the wall plate Locking Screw Installation You must install the locking screws before you attach the mounting bracket to the back of the flat panel The locking screws consists of two 2 M6 x 75mm screws Thread one 1 locking screw into the bottom mounting hole on each of the mounting brackets Make sure the locking screw is ...

Page 10: ...y available Lock It Security Barrel Locking Screw Do not thread the locking screw any further once it is even with the mounting tab see illustration to the right Threading the locking screw any further will prevent you from safely attaching the flat panel to the wall plate Mounting Tab Ultilizing the Security Barrel This section presumes that you have read and understood these sections Selecting t...

Page 11: ...o the rails of the wall plate Proceed to the Mounting Bracket Adjustments section Attaching the Flat Panel to the Wall Plate M6 x 75mm Locking Screw 1 per Bracket M6 x 75mm Leveling Screw 1 per Bracket If your flat panel is tilted too far to one side the leveling screws will allow you compensate for this tilt by simply adjusting the screws with a screwdriver n n Loosen both locking screws o o Adju...

Page 12: ...nce for your flat panel PCB CSL1 Security Cable n n Thread the cable through the hole on the security barrel o o Attach the PCB CSL1 locking mechanism and secure it using the supplied key Padlock n n Place the locking hook through the hole of the security barrel o o Snap lock and locking hook together Padlock Combination or Keyed PCB CSL1 4 50 114 30 4 50 114 30 16 50 419 10 17 62 447 60 MIN VESA ...

Page 13: ...splays projectors other property or personal injury resulting in whole or in part from improper installation modification use or misuse of its products NOTWITHSTANDING ANYTHING TO THE CONTRARY IN THIS WARRANTY THIS WARRANTY IS LIMITED TO FIVE YEARS FROM THE DATE OF PURCHASE IN THE EVENT THAT THE WARRANT ED PRODUCT IS COMMERCIALLY RENTED OUT Electrical products and components such as amplifiers spe...