background image

ITEM  # 

52321 / LL2000

 

Submersible Waterfall Pump 

2000 Gallons Per Hour 

PACKAGE CONTENTS 

  WARNINGS AND CAUTIONS 

WARNING 

Risk  of  electrical  shock.  This  pump  is  supplied  with  a  grounding  conductor  and  grounding–type
attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly
grounded, grounding-type receptacle.

Do not exceed the voltage shown on the pump.

Always  disconnect  pump  from  the  power  source  before  beginning  any  maintenance  or  work  on  the
pump.

Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if
damage is found.

Do not remove the grounding pin from the power cord plug.

Risk  of  electrical  shock:  This  pump  has  not  been  investigated  for  use  in  swimming  pools  or  marine
areas.

CAUTION 

This pump has been evaluated for use with water only.

Use a proper power source as indicated on the pump label.

Keep the cord away from high temperatures or other heat sources.

Do not pump heated liquids.

Do not let the pump run dry.  Pump must be completely submerged for proper operation and cooling.

Operate in fresh water only.  Avoid heavily chlorinated water and water with high pH levels.

Do not lift the pump by its power cord.

Part 

Description 

Quantity 

Pump 

1 in. and 1-1/2 in. ID tubing 

adapter 

pump barrier bag 

Questions, problems, missing parts? 

Before returning 

to your retailer, call our customer service department at  
1-888-412-6001, 8 a.m.-6 p.m., EST, Monday-Friday, or
email us at [email protected].  Or visit our
website www.totalpond.com.

REMINDER 

CALL 1-888-412-6001 

BEFORE RETURNING TO STORE. 

B

Summary of Contents for LL2000

Page 1: ...ump has not been investigated for use in swimming pools or marine areas CAUTION This pump has been evaluated for use with water only Use a proper power source as indicated on the pump label Keep the cord away from high temperatures or other heat sources Do not pump heated liquids Do not let the pump run dry Pump must be completely submerged for proper operation and cooling Operate in fresh water o...

Page 2: ... water flow it is recommended that the largest tubing size for your pump is used If using 1 in ID tubing proceed to step 2 If using 1 1 2 in ID tubing cut the adapter as shown using a hacksaw Fig 1 Fig 1 2 Connect tubing to the outlet of the pump using an adapter Fig 2 NOTE Tubing is NOT INCLUDED Fig 2 3 Place the pump inside the pump barrier bag Pull the drawstring until the pump barrier bag is f...

Page 3: ...mbly into the pump to potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing Use thick gloves when replacing the impeller assembly Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing Refer to the diagram in the replacement parts list TROUBLESHOOTING If the pump fails to operate Check to make sure the power cord i...

Page 4: ...30 11 470 1 080 1 780 3 410 10 581 1 215 2 009 3 580 9 655 1 310 2 240 3 720 8 696 1 426 2 490 3 870 7 792 1 532 2 660 4 020 6 887 1 664 2 850 4 150 5 940 1 770 3 050 4 320 4 1 077 1 849 3 197 4 480 3 1 120 1 940 3 348 4 660 2 1 301 2 034 3 440 4 830 1 1 374 2 134 3 560 5 000 0 1 450 2 250 3 700 5 150 LL1200 LL2000 A LL3600 A LL5100 Waterfall Pumps Printed in China ...

Page 5: ...y does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should not be relied upon by the user...