![Toss RESISTRON ROPEX RES-409 Operating Instructions Manual Download Page 52](http://html1.mh-extra.com/html/toss/resistron-ropex-res-409/resistron-ropex-res-409_operating-instructions-manual_1138659052.webp)
Maintenance
Page 52
RES-409
[X] As of February 2007:
With ROPEX visualization software or via CAN-Bus
interface only.
12
Maintenance
The controller requires no special maintenance.
Regular inspection and/or tightening of the terminals –
including the terminals for the winding connections on
the impulse transformer – is recommended. Dust
deposits on the controller can be removed with dry
compressed air.
Measuring impulse
length
[X]
Measuring impulse length: 1.7ms
Temperature
diagnosis
[X]
Temperature diagnosis: OFF
Heatup timeout
[X]
Heatup timeout: OFF
Output 1
[X]
„Temperature OK“-Bit:
aktive if T
act
= T
set
Hold mode
[X]
Hold mode: OFF
DIP switch
for identifier and
baudrate
As of February 2007:
Identifier = 0
Baudrate = AutoBaud
Termination = ON
Up to January 2007:
Identifier = 1024
dez
Baudrate = 205kBaud
Termination = ON
3
8
2
9
1
10
4
7
5
6
6 7 8
ON
OFF
1