Summary of Contents for TW09HQ2C2AO

Page 1: ......

Page 2: ...TW09HQ2C2AO WIFI TW09HQ2C2DO WIFI TW12HQ2C2AO WIFI TW12HQ2C2DO WIFI TW18HQ2C2DO WIFI TW24HQ2C2DO WIFI TW09HQ3C2AO WIFI TW09HQ3C2DO WIFI TW18HQ3C2DO WIFI TW24HQ3C2DO WIFI ...

Page 3: ...for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If it needs to install move or maintain the air conditioner plea...

Page 4: ...at if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION WARNING CAUTION DANGER NOTICE ...

Page 5: ... appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electri...

Page 6: ...damage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause obje...

Page 7: ...cables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity plea...

Page 8: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refri...

Page 9: ...e the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range Indoor side DB WB C F Outdoor side DB WB C F Maximum cooling 26 7 19 4 80 66 9 46 1 23 9 115 75 Maximum heating 26 7 80 23 9 18 3 75 64 9 The opera...

Page 10: ...Parts Name Outdoor Unit 6 NOTICE Actual product may be different from above graphics please refer to actual products air inlet Connection wire air outlet ...

Page 11: ...stallation dimension diagram Space to the wall Above A b o v e 50cm Air inlet side 0 0 Space to the obstruction Air outlet side 0 2 m c 0 Above Above 30cm 3 0 c m Space to the wall Drainage pipe Abov e 50cm ...

Page 12: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that connection pipe is securely connected before the compr...

Page 13: ...l not affect neighborhood 2 The location should be well ventilated and dry in which the outdoor unit Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for i...

Page 14: ...ion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance shou...

Page 15: ...t joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step two install drain joint Only for cooling and heating unit 1 Connect the outdoor drain joint into the hole on the chassis as shown in the picture...

Page 16: ...hem with screws 12 18 15 24K Indoor unit connection 09 12K 115V 09 12K 208 230V 1 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe 2 Pretightening the union nut with hand 3 Tighten the union nut with torque wrench by referring to the sheet below gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 ...

Page 17: ...nd heating unit Note Never cut the power connection wire to prolong or shorten the distance During heating operation the condensate and defrosting water should be drained out reliably through the drain hose Install the outdoor dr ain connector in a Φ25 hole or Φ42 hole on the base plate and attach the drain hose to the co nnector so that the waste water formed in the outdoor unit can be drained ou...

Page 18: ...objects for reference The 18K 24K UNIT drainage hole consists of two Φ25 and two kidney holes see the fig 1 The drain plug consists of one Φ25 and two kidney plugs drain holes drain holes drain holes Drain plug Hose available commercially inner dia 16mm Drain connecter Fig 1 Installation of outdoor unit ...

Page 19: ...sure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent 7 Reinstall the handle Use vacuum pump liquid valve gas valve refrigerant charging vent nut of refrigerant charging vent vacuum pump piezometer valve cap Lo Hi inner hexagon spanner open ...

Page 20: ...r damaging the parts Is there any obstruction in the air inlet and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely heating capacity 1 Preparation of test operation The client approves the air conditioner Specify the important notes for air condit...

Page 21: ... requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 15 25 15 30 15 30 20 30 25 30 Cooling capacity Max length of connec tion pipe Cooling capacity Max length of conne...

Page 22: ...07C R410A and R134a Diameter of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ9 52 or Φ12 Φ12 Φ16 Φ19 Φ22 2 Φ16 or Φ19 Φ19 or Φ22 2 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle ...

Page 23: ...downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Note diameter please refer to the sheet below expander hard mold pipe F Inspection If there is any blemish expand the port again according to the steps above the length is equal improper expanding leaning damaged surfac...

Page 24: ...66129927225 ...