AIR CONDITIONER

Owner's Manual

Original Instructions

Split Air Conditioner

 

Thank you for choosing commercial air conditioners.Please read 

this Owner’ s Manual carefully before operation and retain it for 

future reference.

If you have lost the Owner's Manual, please contact the local agent 

or visit www.gree.com or send an email to [email protected] for 

the electronic version.

Summary of Contents for GWH09AAB-K6DNA1A/I

Page 1: ...or choosing commercial air conditioners Please read this Owner s Manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visit www gree com or send an email to global gree com cn for the electronic version ...

Page 2: ...A3A I GWH09AAB K6DNA1A I GWH12AAB K6DNA1A I GWH24AAD K6DNA5A I GWH18AAD K6DNA5B I GWH18AAD K6DNA5A I GWH09AAB K6DNA5A I GWH12AAB K6DNA5A I GWH18AAD K6DNA4A I GWH18AAD K6DNA4B I GWH24AAE K6DNA4C I GWH24AAD K6DNA4A I GWH09AAB K6DNA4A I GWH12AAB K6DNA4A I GWH09AAB K6DNA1B I GWH09AAB K6DNA2B I ...

Page 3: ...Malfunction Malfunction analysis 13 Installation Notice Installation dimension diagram 18 Tools for installation 20 Selection of installation location 20 Requirements for electric connection 21 Installation Installation of indoor unit 22 Check after installation 27 Test and operation Test operation 27 This appliance is not intended for use by persons including children with reduced physical sensor...

Page 4: ... by the manufacture Should repair be necessary contact your nea rest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Appliance shall be installed operated and stor...

Page 5: ...ppliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric ...

Page 6: ...l injury or damage WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Page 7: ...bles before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please...

Page 8: ... should be connected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Page 9: ...the line For the air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location which is out of reach for children and reachable after finishing installation For the air conditioner with plug the plug should be Working temperature range NOTICE 6 Indoor side DB WB Outdoor side DB WB Maximum cooling 32 23 4...

Page 10: ... Unit remote controller NOTICE Actual product may be different from above graphics please refer to actual products 7 Display content or position may be different from above graphics please refer to actual products air inlet panel aux button horizontal louver air outlet temp indicator power indicator receiver window ...

Page 11: ... heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light function Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel function X fan mode health function ventilation operation 2 5 7 9 4 12 3 1 6 8 10 11 NOTICE This is a general remote controller Some mo...

Page 12: ...t Mode button 2 Each time you press this button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT as the following AUTO COOL DRY FAN HEAT Note Only for models with heating function This is a general use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresponding button on the remot...

Page 13: ... HOUR ON OFF will flash to be displayed Meanwhile press button or button to adjust timer setting time Press this button you can see indoor set temperature indoor ambient temperature on indoor unit s display The setting on remote controller is selected circularly as below no display Turbo button Press this button to activate deactivate the Turbo function Under COOL or HEAT mode Introduction for butt...

Page 14: ...EMP and TIMER simultaneously in COOL mode to start e nergy saving function 46 if Fahrenheit is adopted Repeat the operation to quit the function Combination of TEMP and TIMER buttons About 8 Heating Function Press TEMP and TIMER simultaneously in HEAT mode to start 8 Heating Function Nixie tube on the remote controller displays and a selected temperature of 8 1 Press the back side of remote contro...

Page 15: ...dicated in the fig Use dust catcher or water to clean the filter When the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly 12 Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoi...

Page 16: ...Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit and then try it again Check whether remote cont roller appears to be d...

Page 17: ...door air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperature exceeds the set temperature range Set tempera...

Page 18: ...ently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal conditions it may cause WARNING When air conditioner status is abnormal temperature indicator on indoor unit will ation of error code Whether there s inter ference such as thunder wireless devices etc Disconnect power put back power and then turn on the unit again Air conditio ner op...

Page 19: ... Check whether the maintenance area is well ventilated The continuous ventilation status should be kept during the operation process Check whether there is fire source or potential fire source in the maintenance area The naked flame is prohibited in the maintenance area and the no smoking warning board should be hanged nameplate Check whether the appliance mark is in good condition Replace the vag...

Page 20: ... pump and it s well ventilated Use the refrigerant filling appliances specialized for R32 Make sure that different kinds of refrigerant won t contaminate with each other After filling is finished please do the leakage detection before test running another time of leak detection should be done when it s removed Please use the flammable gas detector to check before unload and open the container No f...

Page 21: ...18 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall ...

Page 22: ...ry make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that connection pipe is securely connected before the comp...

Page 23: ...n the following places maycause malfunction If it is unavoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other plac...

Page 24: ...copper tube 9 10 Appliance shall be installed operated and stored in a room with a floor area Please notice that the unit is filled with flammable gas R32 Inappropriate larger than Xm treatment of the unit involves the risk of severe damages of people and material Details to this refrigerant are found in chapter refrigerant 2 The appliance shall be installed in accordance with national wiring regu...

Page 25: ...ing to actual wall mounted plate Note Please select the corresponding installation dimensional drawing ac r of Φ55 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 AAD AAB Left Wall Φ55mm Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Spac...

Page 26: ...n end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut with torque wrench 2 When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installat...

Page 27: ... side 1 Connect the drain hose to the outlet pipe of outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe Add insulating pipe in the indoor The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take wiring cover screw panel Step seven connect wire of indoor unit Step six install drain hose indoor unit 2 Bind the joint with tape ...

Page 28: ... pipe and gas pipe should be bound separately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord 25 4 Put wiring cover back and then tighten the screw 5 Close the panel Note All wires of indoor unit and outdoor unit should be connected by a professional for a new one Avoid extend...

Page 29: ...ounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and closed to the wall Note Do not bend the drain hose too excessively in order to prevent blocking indoor outdoor wall pipe sealing gum upper hook lower hook of wall mounting frame Installation of indoor unit 26 ...

Page 30: ...or damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely heating capacit It may cause insufficient cooling heating capacity or waster e...