32
WX9 ASD Installation and Operation Manual
Figure 21. The WX9 ASD Electronic Operator Interface Features.
EOI Features
LED Screen
— Displays the running frequency, active
Fault
, or active
Alarm
information.
LCD Screen
— Displays configuration information, performance data (e.g., output frequency, bus
voltage, torque, etc.), diagnostic information, and
LED
screen information in expanded normal text.
Rotary Encoder
— Used to access the
WX9 ASD
menu selections, change the value of a displayed
parameter, and perform the
Enter
(select) function. Turn the
Rotary Encoder
either clockwise or
counterclockwise to perform the
Up
or
Down
functions of the displayed menu selection. Press the
Rotary
Encoder
to perform the
Enter
(select) function.
HAND/AUTO Key
— Toggles the system to and from the
Hand
and
Auto
modes. The LED is on
when the system is in the
Hand
mode. The
Hand
mode allows the
Command
and
Frequency
control
functions to be carried out via the
EOI
.
The
Auto
mode enables the
Command
and
Frequency
control functions to be carried out via the
Terminal Board
,
RS485
,
Communication Card
,
or
Pulse Input
. The selection may be made via
Program
Fundamental
Standard Mode Selection
Command Mode Selection
ESC Key
— Returns the system to the previous level of the menu tree, toggles between the
EOI
Command
screen and the
Frequency Command
screen, or cancels changes made to a field if pressed
while still in the reverse video mode (dark background/light text). The three functions are menu-specific.
RUN Key
— Issues the
Run
command while in the
Hand
mode. The
RUN
key LED illuminates green
while stopped and red while running or exciting the motor.
MODE Key
— Provides a means to access the root menus. Pressing the
MODE
key repeatedly loops
the system through the root menus (see
). While looping through the root menus, the
Program
menu will display the default
Program
root menu screen item or the
Program
sub-menu item
being accessed prior to pressing the
MODE
key.
STOP/RESET Key
— This key has three functions.
1. Issues the
Off
command (decelerates to
Stop
at the programmed rate) if pressed once.
2. Initiates an
Emergency Off
command if pressed twice quickly. The
Emergency Off
function
terminates the
WX9 ASD
output and will apply the stopping method selected at
.
3. Resets active
Faults
and/or active
Alarms
if pressed twice quickly. The source of the
Fault
or
Alarm
must be determined and corrected before normal ASD operation can resume.
Remove the Phillips screw
first to remove the LED/
LCD display unit to
activate the
system.
LED/LCD Display Unit
Rotary Encoder
LCD Screen
HAND/AUTO Key (LED)
ESC Key
RUN Key (LED)
MODE Key
STOP/RESET Key
LED Screen
Summary of Contents for WX9 ASD
Page 2: ......
Page 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv WX9 ASD Installation and Operation Manual ...
Page 225: ......