TXZ Family
Flash Memory
2018-06-05
68 / 120
Rev. 2.0
5.2.4. [FCSR0] (Flash Status Register 0)
Bit
Bit Symbol
After reset
Type
Function
31:16
-
0
R
Read as “0”
15
-
undefined
R
Read as “undefined value”
14:11
-
0
R
Read as “0”
10
RDYBSY2
1
R
ReadyBusy flag of Area 4
0: In automatic operation
1: Completion of automatic operation
9
RDYBSY1
1
R
ReadyBusy flag of Area 2
0: In automatic operation
1: Completion of automatic operation
8
RDYBSY0
1
R
ReadyBusy flag of Area 0 and Area1
0: In automatic operation
1: Completion of automatic operation
7:1
-
0
R
Read as “0”
0
RDYBSY
1
R
ReadyBusy flag (all flash area)
0: In automatic operation
1: Completion of automatic operation
ReadyBusy flag indicate when automatic programming
command or automatic erasing command is executed.
This bit indicates automatic operation status. When this
bit is “0”, it indicates that the flash memory is busy status
where it is in automatic operation. When automatic
operation is completed, this bit is set to “1”. It indicates
ready status where the register can accept the next
command.