TRANSPORTATION AND INSTALLATION MANUAL
88
Connecting the Brake Cable/Robot Control Signal Cable
8.1.4.
The brake cable is used to input and output an ON/OFF signal for the brake to lock the
motor shaft.
The brake signal cable used to lock the motor shaft is connected to the connector BRK
([4] in Fig. 8.1).
The robot control signal cable is used for input and output of robot control signals such
as hand operation signal.
The robot control signal cable is connected to the connector "HAND" ([3] of Fig. 8.1).
The brake cable/robot control signal cable on the robot side are connected to [2] of Fig.
8.2.
The cables and connectors for the brake cable and robot control signal cable are
standard accessories.
Connecting Power Supply Cable for External Input/Output
8.1.5.
Use the attached connector [ML-4000-CP-5PGY] to connect the power supply cable for
external input/output ("GND, P24V" ([6] in Fig. 8.1)). The P24V power is supplied from
the front of the controller.
Shown below are the input/output signals that use the externally supplied power (24
VDC). Be sure to supply external power (24 VDC).
External input/output
External operation input/output
Extended input/output
Hand input/output
The wires for the connector are AWG24 to AWG16.
Choose the most suitable external power supply for your system specification
(ampacity).
IN_P24G
IN_P24V
ロボットコントローラ側
お客様側
ML-4000-CP-5PGY サトーパーツ製(付属品)
P24V
P24G
EXT I/O
外部24V供給電源
5
4
3
2
1
Terminal board
Externally supplied power (24 VDC)
Produced by Sato Parts Co., Ltd.
(accessory)
TSL3100E
Robot controller side