E6582062
6-29
6. [Advanced] How to use parameters
3
4
6
9
6. 6. 5
Changing frequency by the terminal UP and DOWN
signal
<F264: Terminal Up response time>
<F265: Terminal Up frequency step>
<F266: Terminal Down response time>
<F267: Terminal Down frequency step>
<F268: Initial Up/Down frequency>
<F269: Up/Down frequency rewrite>
■
Function
These parameters are the frequency commands that input the logic signals to the two input
terminals for the UP and DOWN signals. You can input a logic signal either as a continuous signal or
as a pulse signal.
Set <FMOd: Frequency command select 1>= "15".
■
Parameter setting
■
Input terminal parameter setting
Three input terminals are used.
Two of the three input terminals are used for the UP and DOWN signals. The other input terminal is
used for the signal that clears the set frequency command.
Title
Parameter name
Adjustment range
Unit
Default setting
F264
Terminal Up response
time
0.0-10.0
s
0.1
F265
Terminal Up frequency
step
0.0-FH
Hz
0.1
F266
Terminal Down response
time
0.0-10.0
s
0.1
F267
Terminal Down frequency
step
0.0-FH
Hz
0.1
F268
Initial Up/Down
frequency
LL-UL
Hz
0.0
F269
Up/Down frequency
rewrite
0: F268 is not changed.
1: F268 is changed after power off.
1
Input terminal function
ON
OFF
88
Terminal Up frequency
Frequency setting increase
-
90
Terminal Down frequency
Frequency setting decrease
-
92
Terminal Up, Down frequency clear
OFF
→
ON: Input terminal up/
down frequency command
clear
<F268> setting
0.0Hz
STOP
12:59
F264 : TB Up response time
Min: 0.0
Max: 10.0
X1000
X100
X10
X1
0.1
s
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...