3. [Basic operation] Operation panel and screen display
3-20
3
9
3. 2. 4
How to reset trip
If a trip occurs, you can reset it with panel operation.
For how to reset a trip by other than the operation panel (digital input, etc.), refer to [13. 1].
1
Press the [STOP/RESET] key with the trip displayed.
"CLr" blinks in the main area, and "Reset? (STOP)
key" is displayed on the lower side.
• The backlight is red.
It is white when the setting of the backlight is
changed.
2
If you press the [STOP/RESET] key again while
"CLr" is blinking, the trip is reset.
The display on the screen once disappears, and
the screen immediately after power on is dis-
played.
The backlight returns to while.
Important
• If the cause of the trip is not eliminated, a trip occurs again even after reset.
• If the trip is caused by overload protection or overheat or when pre-alarm occurs, the trip
cannot be reset.
For details, refer to [13. 1].
Memo
• The blinking "CLr" returns to the trip display after few seconds if no operation is performed. The
trip is reset only if you press the [STOP/RESET] key while "CLr" is blinking.
• If you press keys other than the [STOP/RESET], it is considered that reset will not be done, and
the screen returns to trip display.
Setting
20.0Hz
Trip
17:20
Monitor
Standard Mode
CLr
Trip reset ? (STOP-Key)
Screen
F
R
HELLO
0.75KW- 1.0HP
200V
VFAS3-2007P
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...