Undervoltage lockout (UVLO) circuit
Undervoltage lockout (UVLO) trips to turn off V
GATE
when V
IN
drops below the minimum value
of V
in_opr
.
Figure 4.3 UVLO timing chart
5.
Product overview
5.1.
TCK401G
5.1.1 Overview
The TCK401G MOSFET driver IC operates over a wide input voltage range of up to 28V.
MOSFET driver IC in a small package
High maximum input voltage: V
IN
(max) = 40V
Wide input voltage range: V
IN
= 2.7 to 28V
Auto output discharge function
Charge pump for V
GATE
Inrush current suppression circuit
Overvoltage lockout (≥28V)
Undervoltage lockout (≤2.7V)
Protection against reverse current from external back-to-back MOSFETs
Package: WCSP6E (0.8 mm x 1.2 mm x 0.55 mm)