DK40i Installation
KSU Mounting Considerations
Strata DK I&M 6/00
3-5
D
K
40
i Installation
6. Set the meter to the “OHMS/Rx1” scale. Place one probe on the ground terminal, and the other
probe on the terminal that produced a reading of zero volts. The reading should be less than 1
ohm.
CAUTION!
If the reading is more than one ohm, then the outlet is not adequately grounded.
If the above tests show the outlet AC voltage is not in range or is not properly
grounded, the condition should be corrected (per Article 250 of the National
Electrical Code) by a qualified electrician before the system is connected.
Alternate or Additional Ground
If the “third-wire” AC ground can not practically be improved or if extreme motor noise or other
disturbance causes system malfunction, or if local area lightning storms exist, a separate direct
ground may be warranted.
Connect a separate earth ground from a cold water pipe or earth grounding rod directly to the FG
screw terminal on the DK40i power supply (see
KSU Mounting Considerations
The Base KSU and the optional Expansion KSU are both designed to be mounted on a wall or
other vertical surface. Toshiba recommends using method 1 or 2 (see
Prior to Installation
1. Loosen the screws on the front cover and the side cover of the Base KSU, remove the covers
details the interior.
2. Place the BATT jumper plug to the On position.
3. Install a CO line board, either the TDDU or TCOU onto the TMAU board
The TCOU provides four loop start CO lines and can accommodate the Caller ID interface
unit.
The TDDU provides four DID lines.
4. Set CO line card switches.
TCOU: Set the TCOU PAD switches (SW400-SW475) to the appropriate position (see
). The factory setting is NORMAL. If CO lines are connected to a PBX or
are in close proximity to the central office the PAD position may be required.
TDDU: Set the TDDU PAD switches to the appropriate position. Also, set the high/low
voltage jumper plugs as required for proper dial pulse operation.
See
5. If you are not installing a TCIU2, skip to
. To install the TCIU2 (see
), align the prongs P20, P21, and P22 over P120, P121, and P122 of the TCOU and
gently press down. Slip the plastic stand-off hook through the hole.
CAUTION!
To prevent system malfunction, DO NOT install TCIU1 in the DK40i system.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...