ISDN Interfaces
RBSU/RBSS and TBSU Interface Units
Strata DK I&M 6/00
16-23
ISDN
Inte
rface
s
BRI Wire Type Recommendations
CAT3 or CAT5 wire is recommended for ISDN BRI customer-premises wiring. While the ISDN
BRI signal works for some distance over almost any wire that is suitable for analog voice service,
better wire enables longer runs. CAT5 provides better 100-ohm impedance matching (at little extra
cost) between the TBSU or RBSU/RBSS circuit and the station Terminal Equipment (TE-1).
Normally the CAT3 or CAT5 wiring does not have to be shielded when used for ISDN BRI
premises wiring. However, the RJ45 jacks on the TBSU and RBSU/RBSS BRI circuits are
shielded and provide a ground shield in the event that shielded modular plugs and cable are used.
Note
If using shielded cable and plugs, cable runs should only be grounded at the DK TBSU
and RBSU/RBSS, RJ45 jacks. To prevent ground loops, do not ground both ends of
shielded cable runs.
Figure 16-13 RBSU/RBSS Location of LEDs and Connector Locations
TBSU and RBSU/RBSS BRI Cable Jacks and Connectors
In the U.S., the standard connector for ISDN equipment is the eight-pin RJ jack. Patch cables have
eight-pole plugs at both ends. The same pinout applies to both ends of an ISDN cable, which is the
practice of the data world. This means that a flat untwisted cable with an RJ modular plug at both
ends will have the locking tab of the plug on one end, “up;” and on the other end, “down,” as
shown in
Note
This is the opposite of telephony “silver satin” cables which have locking tabs on both
ends facing the same direction. Telephony cables cause the pins at either end to crossover
while data cables provide a straight through pin-to-pin connection between modular jacks.
RBSU
Reset Switch
(resets RBSU Firmware)
RS-232C Connector
for Call-Data Monitor
RJ-45 8-pin (shielded)
Modular Connector
BSY
TS
LOS
FS
BSY
TS
LOS
FS
2795
RBSS
3rd Circuit
2nd Circuit
1st Circuit
4th Circuit
BSY
TS
LOS
FS
BSY
TS
LOS
FS
CKT2
CKT1
CKT4
CKT3
TB3 (FG)
TB1 and TB2 (PFT)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...