Initialisation & Test
Program 91-9 System Initialisation
2-2
Strata DK40 Programming Manual Spring 1999
Program 91-9
System Initialisation
Program Type:
Initialisation
Initialised Default:
See individual programs
Program 91-9 Overview
Note
Always run Program 91-9 four times before entering the customer database when
first installing a system or when its software must be set to the default configuration,
but not while system is in service.
CAUTION!
If you run Program 91-9 while the system is in service, it will erase all
program data and drop all calls.
Running Program 91-9 also runs Program 03 and assigns codes to all PCBs (except options)
installed. It also erases all Program 03 option codes for piggyback PCBs, DSS consoles,
DTMF receivers, etc.
Program 91-9 erases all random or programmed data in all Strata DK software programs and
sets all program data to the default value. It automatically runs all other initialisation
Programs 90-00~
*
99, 91-1, and 92-1~9. It also brings back logical and physical ports to their
initialised settings.
Important!
Do not use Program 91-9 if you are only making minor programming changes
and system programming is basically correct.
(QWHU 3URJ 0RGH
0
6SNU
< 4
+ROG
0
6SNU
<
34 36 38 3: 3<
+ROG
0
Program Telephone Exits Program Mode
Repeat a further three times after LEDs 01, 03, 05, 07, and 09 extinguish.
Enter programming mode.
(Do not press [DN] button.)
Press Buttons 01, 03, 05, 07, and 09.
LEDs 01, 03, 05, 07, and 09 must be ON.
LCD Displays:
SYSTEM INITIALISATION