RemotEye ESS Technical Specification
Function
Description
Dimension(L x W x H mm)
94 x 82 x 30.8 mm
Operating Temperature
‐
20 ~ 40
°
C
Operating Humidity
10 ~ 80 % (Non
‐
condensing)
EMC Regulation
CE, FCC Class B
RS-485 Technical Specification
Cable type:
Bidirectional communication possible over a single pair of twisted cables (AWG 16-26).
EOL resistor sizing criteria:
A standard RS-485 node has a rated input impedance of 12Kohms. A standard RS-485 transmitter can't drive
more than 32 devices and one pair of 120 ohm termination resistors.
Termination:
In a transmission line, there are two wires, one to carry the currents from the driver to the receiver and another to
provide the return path back to the driver. RS-485 links are a little more complicated because of the fact that they
have two signal wires that share a termination as well as a ground return path. However, the basic principles of
transmission lines are the same.
For reliable RS-485 communications, it is essential that the reflections in the transmission line be kept as small as
possible. This can only be done by proper cable termination.
Reflections happen very quickly during and just after signal transitions. On a long line, the reflections are more
likely to continue long enough to cause the receiver to misread logic levels. On short lines, the reflections occur
much sooner and have no effect on the received logic levels.
In RS-485 applications require termination at the master node and the slave node furthest from the master.
Maximum run distances
When high data rates are used, the application is limited to a shorter cable. It is possible to use longer cables
when low data rates are used. The dc resistance of the cable limits the length of the cable for low data rate
applications by increasing the noise margin as the voltage drop in the cable increases. The ac effects of the
cable limit the quality of the signal and limit the cable length to short distances when high data rates are used.
The maximum distance of RS-485 without using a repeater is 4000 feet (1220 meters) at baud rates up to
90Kbps. Examples of data rate and cable length combinations vary from 90 kbps at 4000 feet to 10 Mbps at 15
feet
Summary of Contents for RemotEye ESS
Page 2: ......
Page 16: ...10 RemotEye ESS Instruction Manual 201791 002 ...
Page 35: ...RemotEye ESS Instruction Manual 201791 002 29 ...
Page 82: ...76 RemotEye ESS Instruction Manual 201791 002 ...
Page 83: ...RemotEye ESS Instruction Manual 201791 002 77 This Page Left Intentionally Blank ...
Page 84: ......
Page 85: ......