Toshiba RBC-U32PGP-E Installation Manual Download Page 4

4-EN

- 4 -

1114370699

 

„

Attaching adjust corner caps and air 
intake grille

Brand name indication given at factory shipping
Adjust corner cap
* Can be attached at any location.

Indoor unit electrical control box

Wireless Remote Controller Kit
(separate sold parts)
* Can be installed only at this 

location.

Refrigerant 
pipe side

Drain pipe 
side

Omnidirectional 360°

Locations of air intake grille hook knobs 
(attached when the product was shipped)
*  These knobs can be attached on any 

side of the four sides, but attaching 
them on this side is recommended.

Attaching air intake grille

•  Attach the air intake grille by reversing the procedure of 

its removal. The air intake grille of this ceiling panel can 
be attached in four patterns by turning the grille. Select 
the orientation of the grille for alignment when multiple 
ceiling panels are attached or according to customer 
requirements.

• 

Attach the air intake grille so as not to catch the 
louver motor wire.

• 

Be sure to attach the safety strap of the air intake 
grille to the ceiling panel.

Hook hole of ceiling panel

Safety strap 
hook

•  According to customer requirements, the grille orientation of 

the air intake grille and the location of the company name 
indication on the adjust corner cap can be changed as 
shown in the figure (right) for installation of multiple units. 
However, the Wireless Remote Controller Kit (separate sold 
parts) can be installed only at the diagonal corner of the 
drain pipe of the indoor unit. If the Kit is installed at another 
location, it may cause malfunction of the Kit.

Attaching adjust corner caps

  Hook the strap of the adjust corner cap securely to the pin of 

the ceiling panel.

Pin

Claws A (insert to 

fi

 t)

Claws B (press to 

fi

 t)

Insert the two claws A of the adjust 
corner cap into the rectangular holes 
of the ceiling panel in the direction of 
arrow.

Press the adjust corner cap so that 
the three claws B on the back of the 
cap are 

fi

 tted.

Rectangular 
holes

Claws A

Claws B

Firmly press edges of the 
adjust corner cap.

 

CAUTION

• 

Press the three claws B of the adjust corner cap 
firmly as far as they will go, and then check that the 
adjust corner cap is closely attached. Failure to do 
so may result in water leakage.

3. Other descriptions

Checks after Installation

•  Reconfirm that there is no gap between indoor unit and ceiling panel or between ceiling panel and bottom of ceiling.

*  Such gap may result in water leakage or dew drop.

•  Confirm that all wires are connected correctly and firmly.

*  Otherwise, the louver does not work.

•  Confirm that the claws of the adjust corner caps are fitted securely.

*  Improper fitting may result in water leakage.

When Using Wireless Remote Controller

•  For details of the installation, refer to the Installation Manual supplied with the Wireless Remote Controller Kit 

(separate sold parts).

Delivery to Customer

•  When the installation work has been completed, execute a test run to check for normal operation.
  Then explain how to use and maintain the ceiling panel to the customer according to the Owner’s Manual of the indoor unit.
  Ask the customer to keep this installation manual with the Owner’s Manual and Installation Manual of the indoor unit.

Summary of Contents for RBC-U32PGP-E

Page 1: ...nit which may result in injury Electrical work must be performed by a qualified electrician in accordance with the Installation Manual Make sure the air conditioner uses an exclusive power supply The capacity shortage of the power circuit or improper electrical work may result in electric shock or fire Connect the specified wires firmly and clamp them securely so that external force applied to the...

Page 2: ...etaching air intake grille Air intake grille Ceiling panel Adjust corner cap Knobs of air intake grille hooks 2 Safety strap hook Ceiling panel hook hole Hinges 1 Knob Adjust corner cap Adjust corner cap Strap Ceiling panel Open Keep the bracket open Closed Panel fixing bracket Open Close Fig 1 Fig 2 1 Slide the knobs of the hooks of the air intake grille in the direction of arrow 1 and open the g...

Page 3: ...r the four panel fixing brackets Slide the panel fixing bracket while keeping the screw head lower than the bracket The panel fixing screws have been attached to the indoor unit since its shipping 3 Tighten the four panel fixing screws to secure the ceiling panel until it comes into close contact with the indoor unit Fig 5 4 Check that the ceiling panel is in close contact with the ceiling Make su...

Page 4: ...is installed at another location it may cause malfunction of the Kit Attaching adjust corner caps Hook the strap of the adjust corner cap securely to the pin of the ceiling panel Pin Claws A insert to fit Claws B press to fit Insert the two claws A of the adjust corner cap into the rectangular holes of the ceiling panel in the direction of arrow Press the adjust corner cap so that the three claws ...

Reviews: