background image

– 14 –

EN

10

Before asking for repair work

Check the following before asking for repair work.

LEDs on the signal receiving unit  : OFF  

: Blinking (at intervals of 0.5 seconds)

LED colour

: Green

: Green

: Orange

Check those items. If any of those problems remains, stop the operation and turn off the power. Contact the dealer 
whom you purchased the air conditioner from. Convey the air conditioner model name, wireless remote controller kit 
model name, wireless remote controller model name, signal receiving unit model name and details of the error 
(including LED flashing state). Do not repair any unit by yourself as it is dangerous.

Check again

Phenomenon

Possible cause

Measures

Operation does 
not start even if 
the switch is 
turned on.

The air conditioner is not working or a power failure 
has occurred.

Push START/STOP 

 button on the 

remote controller again.

The power switch is not turned on.

Turn on the power switch if it is off.

The air conditioner is in the ON timer operation.

Cancel the timer operation.

The batteries of the remote controller have been 
exhausted.

Replace the batteries.

The LEDs on the signal receiving unit are not in 
normal state or operation mode is not correct.

Change the operation mode.

Is not the state of the display lamp “Disagreement of 

 

(cool) and 

 

(heat)” or “A (Automatic operation)”?

Change the operation mode.

Dual swing, cycle swing, individual louver position, or power-saving 
cannot be set.

This type of remote controller cannot set 
such functions.

Contact the dealer from whom you purchased the air conditioner. 

Phenomenon

Possible cause

The LEDs flash.

Communication error between signal receiving unit and indoor unit or 
address setup error when the wired remote controller is used

Communication error between indoor unit and outdoor unit

The protective device of the indoor unit is activated.

The protective device of the outdoor unit is activated.

Temperature sensor error

The compressor of the outdoor unit is protected.

The air conditioner is performing a test run.

14-EN

+EH99950501.BOOK  Page 14  Thursday, June 18, 2015  10:57 AM

Summary of Contents for RBC-AX32UW-UL

Page 1: ...ss remote controller kit Model name RBC AX32U W UL Generic model name Wireless remote controller model name RBC AX32U W UL WH L15SE Signal receiving unit model name SX W3BQ AIR CONDITIONER SPLIT TYPE Owner s Manual EH99950501 BOOK Page 1 Thursday June 18 2015 10 57 AM ...

Page 2: ...ler 13 10 Before asking for repair work 14 Thank you very much for purchasing TOSHIBA Carrier Remote controller for Air Conditioner Please read this owner s manual carefully before using your Remote controller for Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner ...

Page 3: ...oner is continuously operated with something abnormal it may cause machine failure electric shock fire or other trouble Reinstallation and repair Do not repair any unit by yourself Whenever the air conditioner needs repair make sure to ask the dealer to do it If it is repaired imperfectly it may cause electric shock fire or other trouble When reinstalling the air conditioner contact with the deale...

Page 4: ...er will indicate the time regardless of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller the clock panel will indicate AM 0 00 and will flash 1 TIMER or button Push the TIMER or button to set the current time Each push of the TIMER button changes the time in one minute steps Pushing the TIMER button continually changes the time in te...

Page 5: ...ush the SWING button to stop the louver swinging A receiving beep is heard 7 Set louver button FIX Push this button to adjust the airflow direction A receiving beep is heard It cannot be operated by holding down the button Push the button with some interval 8 Off timer button OFF Push this button to set the OFF timer 9 On timer button ON Push this button to set the ON timer 10Reserve button SET Pu...

Page 6: ...smission mark This transmission mark indicates when the remote controller transmits signals to the indoor unit 2 Mode display Indicates the current operation mode A Auto changeover control Cool Dry Heat Fan only 3 Temperature display Indicates the temperature setting 62 F to 86 F When you set the operating mode to Fan only no temperature setting is indicated 4 FAN speed display Indicates the selec...

Page 7: ... signal sent from the remote controller is received 3 Display lamp One of displays flashed while an error occurs When the display lamp flashes refer to Before asking for repair work 4 lamp Green This lamp illuminates when unit is on 5 lamp Green This lamp illuminates while the timer is reserved 6 lamp Orange In heating operation this lamp illuminates in the following cases The operation has starte...

Page 8: ...tion auto changeover Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button Set the desired temperature 4 Fan speed button FAN Set a desired fan speed Five patterns are displayed but LOW is equal to LOW and MED to MED The OPERATION lamp green on the display lamp of the signal receiving unit lights The operating mode is select...

Page 9: ...en Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Quiet operation The QUIET mode provides quiet operating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Push the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button P...

Page 10: ...is a OFF timer operation with automatic temperature and fan speed adjustment 1 Push the COMFORT SLEEP button Select 1 3 5 or 9 hours for the OFF timer operation CAUTION The COMFORT SLEEP mode is not enabled in the DRY or FAN ONLY operation When Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Sleep timer operation To start the sleep t...

Page 11: ...time lag of up to 15minutes will occur If you do not push the SET button within 30 seconds after setting the time the setting will be cancelled Once you select the timer operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button of the remote controller If the clock display is f...

Page 12: ...mer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Push the ON TIMER button to adjust the ON timer 2 Push the OFF TIMER button to adjust the OFF timer 3 Push the SET button 4 After step 3 an arrow mark or flashes for about 3 seconds and during this flashing push the SET button During the every day...

Page 13: ...g SWING operation Stop the SWING operation before changing the louver angle Do not operate the air conditioner for long hours with the airflow direction set downward during the cooling or dry operation Otherwise condensation may occur on the surface of the vertical airflow louver and cause dew dripping 8 Mounting remote controller holder Direct the transmitter of the remote controller toward the s...

Page 14: ...e controllers do not display A The factory default of the wireless remote controllers is A A B selection can be set with signal receiving unit For the further details refer to the installation manual 9 Operating air conditioner without remote controller In the following cases the air conditioner can be operate without remote controller with temporary operation button on the signal receiving unit T...

Page 15: ...e air conditioner is in the ON timer operation Cancel the timer operation The batteries of the remote controller have been exhausted Replace the batteries The LEDs on the signal receiving unit are not in normal state or operation mode is not correct Change the operation mode Is not the state of the display lamp Disagreement of cool and heat or A Automatic operation Change the operation mode Dual s...

Page 16: ...EH99950501 EH99950501 BOOK Page 31 Thursday June 18 2015 10 57 AM ...

Reviews: