– 2 –
FILE NO. SVM-12085
Original instruction
Adoption of New Refrigerant
This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional
refrigerant R22 in order to prevent destruction of the ozone layer.
CONTENTS
SAFETY CAUTION
................................3
1. SPECIFICATIONS
..............................14
1-1. Outdoor Unit
..............................14
1-2. Operation Characteristic Curve
..............................15
2. CONSTRUCTION VIEWS (EXTERNAL VIEWS)
..............................17
2-1. RAV-SP40
*
ATP
*
, SP45
*
ATP
*
, SP56
*
ATP
*
..............................17
2-2. RAV-SP80
*
ATP
*
..............................18
3. SYSTEMATIC REFRIGERATING CYCLE DIAGRAM
..............................20
3-1. Indoor Unit
..............................20
3-2. Outdoor Unit
..............................21
4. WIRING DIAGRAM
..............................24
4-1. RAV-SP40
*
ATP
*
, SP45
*
ATP
*
, SP56
*
ATP
*
..............................24
4-2. RAV-SP80
*
ATP
*
..............................25
5. SPECIFICATIONS OF ELECTRICAL PARTS
..............................26
6. REFRIGERANT R410A
..............................27
6-1. Safety During Installation/Servicing
..............................27
6-2. Refrigerant Piping Installation
..............................27
6-3. Tools
..............................31
6-4. Recharging of Refrigerant
..............................31
6-5. Brazing of Pipes
..............................32
6-6. Instructions for Re-use Piping of R22 or R407C
..............................34
6-7. Replenishing refrigerant
..............................37
7. OUTDOOR CONTROL CIRCUIT
..............................38
7-1. Outdoor Controls
..............................38
7-2. Outdoor Print Circuit Board
..............................45
8. TROUBLESHOOTING
..............................47
8-1. Summary of Troubleshooting
..............................47
8-2. Troubleshooting
..............................49
8-3. Table Inspection of outdoor unit main parts
..............................74
9. OTHERS
..............................75
9-1. Refrigerant Recovery Control
..............................75
9-2. Various Setting on Outdoor Unit
..............................76
(Existing piping, Power save, Cooling-only, etc.)
9-3. Service Support Function (LED Display, Switch Operation)
................................77
10. DETACHMENTS
..............................83
10-1. RAV-SP40
*
ATP
*
, SP45
*
ATP
*
, SP56
*
ATP
*
..............................83
10-2. RAV-SP80
*
ATP
*
..............................91
11. EXPLODED VIEWS AND PARTS LIST
............................101
11-1. RAV-SP404ATP-E, SP454ATP-E
............................101
11-2. SP564ATP-E, SP564ATJP-E
............................105
11-3. RAV-SP804ATP-E, SP804ATJP-E
............................109