– 35 –
9
Advanced settings
How to set up swing type
1
Push
for at least four seconds when
the air conditioner is not working.
•
, symbol, and numbers flash.
2
Select an indoor unit to be set by pushing
(left side of the button).
• Each time you push the button, unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
3
Select a swing type by pushing TIME
buttons.
CAUTION
Do not set the swing setup code to “0000”.
(This setting may cause a failure of the louvers.)
4
Push the
button.
5
Push the
button to finish the setting.
2
1
4
5
3
Swing setup code
Swing of louvers
0001
Standard swing
(Factory default)
0002
Dual swing
0003
Cycle swing
Not
display
Unit No.
1-1
Unit No.
2-1
Unit No.
3-1
Unit No.
4-1
Swing setup code
▼
Standard swing
All four louvers swing simultaneously at the same
angle.
▼
Dual swing
Adjoining louver alternately swing horizontally and
downward.
▼
Cyclic swing (Recommended for cooling)
All four louvers swing at different times like waves.
Swing
Horizontal
Downward
Downward
Horizontal
Downward
Downward
Horizontal
Horizontal
69-EN