114
(1)
Common
procedures
Front panel
Top cover
(Continued)
2.
Attachment
1) Attach the top cover.
(6
pcs, M4 × 10 hexagon screws)
2)
Connect the power and indoor / outdoor connection
wires to the terminal.
* Check that the clamp filter is attached to the
ground of the inside-outside connection wiring.
3)
Fix each wire
tightly
to the valve fixing plate with the
cable-ties.
Measure the diameter of the wire to be fixed, and
fasten the wire with the supplied cable-ties (T50R-
HSW from HellermannTyton) so that length A of the
surplus portion of the tie satisfies the following
expression:
A = 183-L
A:
Minimum l
ength of surplus portion of cable-ties (mm)
L:
Circumferential length of wire (mm)
L = Diameter of wire D (mm) ×
π
4)
Cut off the tie surplus portion (A) of the cable-ties.
Cable-ties specifications
CAUTION
• An installation fuse must be used for the power
supply line of this air conditioner.
• Incorrect / incomplete wiring may lead to an electrical
fire or smoke.
• Prepare a dedicated power supply for the air
conditioner.
5) Attach the terminal cover.
(2 pcs, M4 × 8 truss screws)
6) Attach the front panel.
(3 pcs, M4 × 10 hexagon screws)
(2)
Side cabinet (left)
1. Detachment
1) Following to work of Detachment of (1).
2) Remove the stay plate screws while holding the stay
plate by hand.
(2 pcs, M4 × 10 hexagon screws)
2. Attachment
Attach the stay plate in the reverse process of
“
1. Detachment
”.
No.
Part name
Procedure
Remarks
Model
Material
Flame
retardant
grade
Manufacturer
T50R-HSW
Nylon 66
UL94V-2
Hellermann
Tyton
Cable-tie
Valve fixing plate
Power supply wire
Indoor / Outdoor
connecting wires
Cable-tie
A
Valve fixing plate
D
Wires
Stay plate