(5)
Side cabinet
1. Side cabinet (right)
1) Following to work of Detachment of (2) and (3).
2) Remove the fixing screws (3 pcs, M4 × 8 truss
screws) used for securing the side cabinet (right) to
the bottom plate and valve fixing plate.
2. Side cabinet (left)
1) Following to work of Detachment of (2).
2) Remove the fixing screw (1 pc, M4 × 10 hexagon
screw) used for securing the side cabinet to the
bottom plate.
3) Remove the fixing screws (2 pcs, M4 × 8 truss
screws) used for securing the side cabinet to the
heat exchanger.
(6)
Fan motor
1) Following to work of Detachment of (2) and (3).
2) Remove the flange nut fixing the fan motor and the
propeller.
• Flange nut is loosened by turning clockwise.
(To tighten the flange nut, turn counterclockwise.)
3) Remove the propeller fan.
4) Disconnect the connector for fan motor from the
inverter.
5) Remove the fixing screws (4 pcs, M4 × 8 truss
screws) holding by hands so that the fan motor does
not fall.
* Precautions when assembling the fan motor.
Tighten the flange nut using a tightening torque of
4.9 N•m.
No.
Part name
Procedure
Remarks
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Side cabinet
(right)
Hock
Hock
Hock
Hock
Hock
Hock
Hock
Hock
Hock
Bottom
plate
Bottom
plate
Bottom
plate
Bottom plate
Bottom plate
Bottom plate
Bottom
plate
Bottom
plate
Bottom
plate
Detail A
Detail A
Detail B
Detail B
Detail C
Detail C
Side cabinet (right)
Side cabinet (right)
Side cabinet (right)
Valve fixing plate
Valve fixing plate
Valve fixing plate
Bottom plate
Bottom plate
Bottom plate
A
A