Operation mode
:
Cooling
Power supply voltage
:
220V
Operatin
Indoor unit
Unit capacity (kW)
Cooling capacity (kW) Power consumption (W) Operating current (A)
Power factor (%)
EER
status
A
B
C
D
E ΣkBTU
A
B
C
D
E
Min
Rate
Max
Min
Rate
Max
Min
Rate
Max
Min Rate Max Rate
3 units
22
10
07
-
-
39
4.15
1.87
1.38
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
(continued)
24
10
07
-
-
41
4.45
1.69
1.25
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
13
13
07
-
-
33
2.91
2.91
1.57
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
16
13
07
-
-
36
3.26
2.68
1.45
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
13
07
-
-
38
3.46
2.56
1.38
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
13
07
-
-
42
3.79
2.34
1.26
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
24
13
07
-
-
44
4.10
2.14
1.16
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
16
16
07
-
-
39
3.03
3.03
1.35
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
16
07
-
-
41
3.22
2.90
1.29
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
16
07
-
-
45
3.60
2.70
1.20
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
24
16
07
-
-
47
3.92
2.48
1.10
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
10
10
10
-
-
30
2.47
2.47
2.47
-
-
3.9
7.4
8.6
960
1975
2750
4.85
9.45
12.76
90
95
98
3.75
13
10
10
-
-
33
3.01
2.20
2.20
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
16
10
10
-
-
36
3.36
2.02
2.02
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
10
10
-
-
38
3.56
1.92
1.92
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
10
10
-
-
42
3.89
1.75
1.75
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
24
10
10
-
-
44
4.20
1.60
1.60
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
13
13
10
-
-
36
2.71
2.71
1.98
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
16
13
10
-
-
39
3.06
2.51
1.83
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
13
10
-
-
41
3.25
2.40
1.75
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
13
10
-
-
45
3.63
2.24
1.63
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
24
13
10
-
-
47
3.94
2.06
1.50
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
16
16
10
-
-
42
2.85
2.85
1.71
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
16
10
-
-
44
3.03
2.73
1.64
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
16
10
-
-
48
3.41
2.56
1.53
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
24
16
10
-
-
50
3.72
2.36
1.42
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
13
13
13
-
-
39
2.47
2.47
2.47
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
16
13
13
-
-
42
2.80
2.30
2.30
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
18
13
13
-
-
44
2.98
2.21
2.21
-
-
4.0
7.4
8.8
970
1975
2770
4.90
9.45
12.85
90
95
98
3.75
22
13
13
-
-
48
3.36
2.07
2.07
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
24
13
13
-
-
50
3.67
1.91
1.91
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
16
16
13
-
-
45
2.66
2.66
2.19
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
18
16
13
-
-
47
2.84
2.56
2.10
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
22
16
13
-
-
51
3.17
2.38
1.95
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
24
16
13
-
-
53
3.48
2.21
1.81
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
16
16
16
-
-
48
2.50
2.50
2.50
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
18
16
16
-
-
50
2.68
2.41
2.41
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
22
16
16
-
-
54
3.00
2.25
2.25
-
-
4.1
7.5
9.0
980
2000
2800
4.95
9.57
12.99
90
95
98
3.75
* Applicable FCU are "PKV" series and "BKV" series only.
• The above specification values are those under the conditions that the indoor DB/WB=27/19°C and the outdoor DB/WB=35/
24
°C.
FILE NO. SVM-18051
- 8 -