Item
Operation flow and applicable data,etc
Description
.
2
1
. POWER
Mode
Selection
([POWER-SEL] button on the remote controller
is pressed)
The function is used when its circuit
breaker is
shared with other electrical
appliances.
It limits the maximum
current/ power
consumption to 100%,
75% or 50%.
The lower the percentage, the higher
the saving
and also the longer the
compressor lifetime.
When the level is selected, Power-SEL
level flashes on LCD display for 3
seconds. In case of 75% and 50%
level, number "75" or "50" also flashes
for 2 seconds.
Note :
Due to the reason that POWER
SELECT FUNCTION limits the
maximum current, inadequate
capacity may occur.
−
Power Selection 50% is 50% of rate maximum
−
Power Selection 75% is 75% of maximum
current.
current.
FILE NO. SVM-1
401
7
−
47
−
2
2
. Outdoor
control
Quiet
<With Quiet control/Non-select method>
1. Purpose
For the users who concern about noise
of the outdoor unit, this control controls
the max. revolutions of the compressor
to reduce the noise.
2. Description
To reduce noise, [RESET] button of the
indoor unit is kept pushed for 20
seconds.
The number of revolution for the indoor
fan motor and the seup temp value are
kept as they are.
3. Operation
As shown in the table, the maximum
revolution number of indoor unit
compressor can be reduced.
As the maximum number of revolution
of the compressor is restricted, the rise-
up performance at the start time is
weakened.
Select "Conrol" or "No conrol" by keeping
[RESET] button pushed for 20 seconds.
("No control" at shipment from the factory.)
Exchanging from "No control" to "Control" :
Beep sound is heard (Pi, Pi, Pi, Pi, Pi) and
the operation LED 5Hz flashes for 5
seconds.
Exchanging from "Control" to "No control" :
Beep sound is heard.
(Operation LED does not flash.)
<Maximum number of revolution of compressor at normal time and Quiet control time>
2.
Description
1
.
Purpose
POWER-SELECTION OPERATION
POWER SEL
POWER SEL
POWER SEL
POWER SEL
[100%]
[75%]
[50%]
[100%]
RAS-10G2KVP-E
RAS-13G2KVP-E
RAS-16G2KVP-E
Outside temp. Normail time Ouiet controlled Normail time Ouiet controlled Normail time Ouiet controlled
(TO)
(rps)
(rps)
(rps)
(rps)
(rps)
(rps)
COOL
61
53
58
58
78
64
~ 5°C
93
73
73
7
3
80
76
HEAT
~ 10°C-5°C
93
73
73 73
80
76
- 10°C ~
93
73
73
7
3
80
76