40
–
Item
10. Temporary
operation
Operation flow and applicable data, etc.
Pressing [RESET] button starts the temporary opera-
tion of [AUTO] operation. When keeping [RESET]
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.
Description
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, “Pi” sound is
heard and the temporary [COOL]
operation starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
11. Plasma
ionizer
purifier
control
This function generates nagative ion while cleaning the air in the room.
If plasma ionizer purifier-ON signal is received while the air conditioner stops, the plasma ionizer
purifier starts operation, and if it is received while the air conditioner operates, the air conditioner
and the plasma ionizer purifier start operation.
* When the previous operation was the
operation of air condi plasma
ionizer purifier, an operation of air
condi plasma ionizer purifier starts
by pushing AC button on the remote
controller.
(Operation of air condi plasma
ionizer purifier is stored in memory.)
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1)
→
(L)
→
(L–)
→
(SL).
Filter lamp ON
Press RESET button.
Did you press [RESET] button
for 3 seconds or more?
Did you press [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
Sending plasma ionizer-ON
Operation lamp ON
Fan ON
Plasma ionizer purifier ON
Plasma ionizer purifier operation
Start of plasma ionizer purifier-ON
Operation lamp OFF
Filter-OFF
Memory position of
louver/COOL
Air condi Plasma
ionizer purifier operate
Fan stop
Plasma ionizer purifier-OFF
Louver close
All stop
Air conditioner operates
Sending plasma ionizer purifier-OFF
1 , 2
3
4
, 4
2
Air conditioner operates
1
Air conditioner stops
Plasma ionizer purifier
operates
Air condi
Plasma ionizer purifier
operate
*1
*2
Present status
Stop
Plasma ionizer purifier only
Air conditioner
Joint use of AC and plasma ionizer purifier
Operation button
PURE button
Air conditioner
Plasma ionizer purifier
AC operation*
Stop (All)
AC + Plasma ionizer purifier
AC + Plasma ionizer purifier
All stop
AC operation
All stop
Plasma ionizer purifier operation
AC + Plasma ionizer purifie operation
Louver*1
Cooling position
Follows to AC operation
Fan speed *2
AUTO, L, L+, M, M+, H
Follows to AC operation
FILE NO. SVM-1
40
17
3