
Item
8. Louver control
Operation flow and applicable data, etc.
Description
–
37
–
FILE NO. SVM-1
401
7
2) Louver position in heating operation
Manual and automatic operation
HI-POWER operation
Initial setting is directs downward (43.1°)
Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (43.1°)
Wide-angle
Right wide
Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot air direction
Spot position is directs downward (43.1°)
Wide front
Sport right
Spot left
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)