– 13 –
FILE NO. SVM-03009
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-24UKHP-ES-1, RAS-18UKHP-ES2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
ICF-340-30-F2
DC 340V, 30W
2
Thermo sensor (TA-sensor)
———
10k
Ω
at 25°C
3
DC-DC transformer (T01)
SWT-58A
DC 390V, Secondary DC 15V, 12V, 7V
4
Microcontroller
TMP87CM40AN
5
Heat exchanger sensor
———
10k
Ω
at 25°C
(TC-sensor)
6
Line filter (L01)
SS11V-R07190
19mH, AC 0.7A
7
Diode (DB01)
D3SBA60
4A, 600V
8
Capacitor (C02)
KMH450VNSN120M25C 120
µ
F, 450V
9
Fuse (F01)
TSCR
T6.3A, 250V
10
Power supply IC (IC01)
MA8920
5A, 900V
11
Varistor (R21, R22)
15G561K
560V
12
Resistor (R01)
RF-5TK4R7
4.7
Ω
, 5W
13
Louver motor
MP35EA12
Output (Rated) 2W, 10poles, 1phase,
DC 12V
4-2. Outdoor Unit (RAS-24UAH-ES-1)
No.
Parts name
Type
Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220 – 240V, 50Hz
1
Compressor
PA290X3F-4MS
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
1.07
2.20
Output (Rated) 65W, 6poles, 1 phase, 220 – 240V, 50Hz
2
Fan motor (for outdoor) KFG6-71SB5P-T1 Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
64.4
127.4
3
Running capacitor
451355KQ
AC 450V, 3.5
µ
F
(for fan motor)
4
Running capacitor
371456JCR
AC 370V, 45
µ
F
(for compressor)
5
Solenoid coil
VHV (STF)
AC 220 – 240V
(for 4-way valve)
6
Thermo sensor
TE / TD
10k
Ω
at 25°C / 50k
Ω
at 25°C
7
Magnetic contactor
A35
220 – 240V, 50Hz
8
Transformer
TT-05
220 – 240V
9
Microcontroller
TMP47C840N
10
Varistor (R73, R74)
15G471K
470V
11
Fuse (F01)
MT3
T6.3A, 250V