9-8-2. How to Check Whether the Minus Ion Generator is Good or Not
• How to check output of minusion
<Caution on High Voltage!!>
No trouble
Does the plasma lamp (Blue) or
the filter lamp (Orange) go on?
Replace the main P.C. board (WP-008).
1) Check operation while short-circuiting CN34 of the main P.C. board.
2) Perform air purifying operation by the remote control.
•
In this time, check that the remote control is in status which is shortened by time on
the reactivation preventive timer and all display lamps go on for approx. 3 seconds
when a signal is received.
If time on the reactivation preventive timer is not shortened,
the high-voltage is not applied to electrode of the air purifier for approx. 1 hour.
•
While the air purifier operates, check that the fan speed [AUTO] is not displayed.
(Because the power ON/OFF is controlled on the program)
3) Be sure not to touch the electrode with the human body.
( )
Turn off the power breaker and remove
CN34 (Micro switch connector).
Short-circuit between
1
and
2
pin of
CN34 at PC side, and turn on the
power breaker after 10 seconds.
Does the electrode
output approx.
−
6kV?
Referring to the right figure, check the
high-voltage output of the air ionizer.
In this time, peel the thermal insulator, and attach
it to the original position after check operation.
NOTE :
Use an exclusive high voltage tester; otherwise
the tester may be broken.
Does the plasma lamp
go off within 2 seconds after
it was ON, and does the
filter lamp (Orange) go on?
Does the indoor fan rotate?
Micro-switch is stuck
Micro-switch malfunction
Is there conduction of
micro-switch connector under
ON status of the micro-switch
(Front panel closed)?
Is there conduction of
micro-switch connector under
OFF status of the micro-switch
(Front panel opened)?
Is DC12V applied
between
1
(Red/DC12V) and
2
(Brown/GND) of CN1 of the
high-voltage unit in the air purifier?
Does the OPERATION lamp blink?
Turn off the power breaker once,
and turn on again after 10 seconds.
• Conduction check of micro-switch
Replace micro-switch.
Operation check
Primary check
YES
YES
NO
YES
NO
NO
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
YES
Replace the power P.C. board
(WP-008) or the housing assembly.
Integrated
power supply assembly
Push the switch
ON
Releaes the switch
OFF
ON
Tester
GND
Electrode
High-voltage
unit
High-voltage tester
To item Power supply is not turned on
To item Only indoor fan does not operate
To item How to check whether