2
-1. Specifications
Unit model
Indoor
RAS-10
G2KCVP-T
RAS-13
G2KCVP-T
RAS-18
G2KCVP-T
Outdoor
RAS-10
G2ACVP-T
RAS-13
G2ACVP-T
RAS-18
G2ACVP-T
Cooling capacity
(kW)
2.
6
3.
8
5.
1
Cooling capacity range
(kW)
1.
3
-3.
5
1.
3
-4.1
1.1-6.0
Power supply
1Ph/50Hz/220V
Electric
characteristic
Indoor
Operation mode
Cooling
Cooling
Cooling
Running current
(A)
0.2
4
0.2
4
0.
24
Power consumption
(W)
25
25
25
Power factor
(%)
47
47
47
Outdoor
Operation mode
Cooling
Cooling
Cooling
Running current
(A)
2.9
6
4.
77
7.12
Power consumption
(W)
5
5
5
1035
1
555
Power factor
(%)
92
99
9
9
Starting current
(A)
2.97
5.01
7.36
COP
4.48
3.
58
3.
23
Operating
noise
Indoor
High
(dB-A)
42
42
44
Medium
(dB-A)
33
34
35
Low
(dB-A)
24
25
26
Outdoor
(dB-A)
49
50
52
Indoor unit
Unit model
RAS-10
G2KCVP-T
RAS-13
G2KCVP-T
RAS-18
G2KCVP-T
Dimension
Height
(mm)
293
Width
(mm)
831
Depth
(mm)
270
Net weight
(kg)
14
Fan motor output
(W)
3
0
30
Air fl ow rate
(m3/min)
1
0.8
1
1.2
1
1.6
Outdoor unit
Unit model
RAS-10
G2ACVP-T
RAS-13
G2ACVP-T
RAS-18
G2ACVP-T
Dimension
Height
(mm)
550
550
Width
(mm)
780
780
Depth
(mm)
290
290
Net weight
(kg)
3
7
3
6
Compressor
Motor output
(W)
1100
Type
750
Single rotary type with DC inverter variable
speed control
Twin rotary type with
DC inverter variable
speed control
Model
DA108
X
1C-23FZ
DA13
1S1B-31FZ
Fan motor output
(W)
43
43
Air fl ow rate
(m3/min)
30
37.5
3
4.0
Piping
connection
Type
Flare connection
Flare connection
Indoor unit
Liquid side
(mm)
Ø6.35
Ø6.35
Gas side
(mm)
Ø9.52
Ø12.70
Outdoor unit
Liquid side
(mm)
Ø6.35
Ø6.35
Gas side
(mm)
Ø9.52
Ø12.70
Maximum length
(m)
20
20
(m)
15
15
Maximum chargeless length
Maximum height difference
(m)
10
10
Refrigerant
Name of refrigerant
R410A
R410A
Weight
(kg)
1.40
Wiring
connection
Power supply
1.1
3Wires:includes earth(Outdoor)
Interconnection
4Wires:includes earth
Usable temperature range
Indoor
(°C)
21~32
Outdoor
(°C)
-10~43
Accessory
Indoor unit
Installation plate
1
Wireless remote controller
1
Batteries
2
Remote controller holder
1
Mounting screw
6(Ø4x25L)
Remote controller holder
Pan head wood screw
2(Ø3.1x16L)
Installation manual
1
Owner’s manual
1
Outdoor unit
Drain nipple
-
Water-proof rubber cap
-
*
The specifications may be subject to change without notice for purpose of improvement.
2
. SPECIFICATIONS
FILE NO. SVM-15058
- 6 -