Item
7
. Louver control
Operation flow and applicable data, etc.
Description
2)
Wind
direction
adjustment
•
The
Up-Down
louver
position can
be
arbitrarily set up by
pressing [FIX
] button.
•
Swing operation is perfor in range 35° with the Fixed position as
the center.
•
If the swing range exceeded either upper or lower limit position,
swing operation is perfomed in range 35° from the limit.
3) Swing
•
Fixed
Position
before start
swing
Upper Limit
Position.
Lower Limit
Position
30
o
5
o
Swing
range 35
o
Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
Upper Limit
Position.
Lower Limit
Position.
Fixed Position
before start
swing.
17.5
o
17.5
o
Swing
range 35
o
Horizotal blowing
Inclined blowing
Inclined blowing
Blowing downward
Front blowing
Left blowing
Right blowing
Front blowing
•
The
Left-Right
louver
position can
be
arbitrarily set up by
pressing [FIX
] button.
•
Up-Down and Left-Right
louver are same setting.
FILE NO. SVM-15058
- 36 -