8
EN
NOTE
• Make sure the wire length is sufficient before performing wiring work.
How to connect the connecting cable
Wiring the connecting cable can be carried out without removing the front panel.
1.
Remove the air inlet grille. Open the air inlet grille upward and pull it toward you.
2.
Remove the terminal cover and cord clamp.
3.
Insert the connecting cable (or as according to local regulations/codes) into the pipe hole on the wall.
4.
Pull the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm out of the front.
5.
Insert the connecting cable fully into the terminal block and secure it tightly with screws.
Make a loop with the earth wire under the terminal block and secure it with the earth screw.
6.
Tightening torque: 1.2 N·m (0.12 kgf·m)
7.
Secure the connecting cable with the cord clamp.
8.
Attach the terminal cover, rear plate bushing and air inlet grille on the indoor unit.
CAUTION
A switch or circuit breaker that can disconnect all poles must be included in the fixed wiring. Be sure to use an approved circuit
breaker or switch.
Wiring Connection
CAUTION
• Be sure to refer to the wiring system diagram labeled inside the front panel.
• Check local electrical regulations for any specific wiring instructions or limitations.
10 mm
110 mm
10 mm
50 mm
Screw
NOTE
• Connecting cable
(Indoor unit/outdoor unit)
• Wire type:
H07RN-F or 60245IEC66
(1.0 mm
2
)
Earth line
Connecting cable
Connecting cable
Cord clamp
Terminal cover
Terminal block
Earth wire
about 15 cm
Screw
Terminal block
Earth wire
(loop)
Earth screw