– 66 –
FILE NO. SVM-02001
10-2. Outdoor Unit (RAS-13UAH-E)
No.
Part name
Procedures
Remarks
1
2
3
4
Common
procedure
Capacitor for
compressor
Capacitor for
fan motor
Overload relay
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC supply.
2) Remove Electric parts cover.
(2-Screws
∅
4 x 10L)
3) Remove the cord clamp (2-Screws
∅
4 x 12L)
and disconnect the connecting cable.
4) Remove the front cabinet.
(7-Screws
∅
4 x 10L with nylon washer)
Pull the front lower portion toward you, and
remove it pulling out upward.
1) Perform the common procedure
1
.
2) Remove the fixing screw and the capacitor band.
(1-Screw
∅
4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure
1
.
2) Remove the fixing screw and the capacitor band.
(1-Screw
∅
4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure
1
.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull up
the overload relay.
4) Disconnect the lead wires.
2-Screws
∅
4 x 12L
2-Screws
∅
4 x 10L
Remove
7-Screws
∅
4 x 10L
For compressor
For fan motor
Overload relay