
FILE NO. SVM-02003
– 18 –
5-5. RAS-10UKX / RAS-10UASX
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH102T1-4C
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
9.52
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R-22 : 0.65 kg.
Evaporator
Capillary tube
∅
1.5x1400
S
Accumulator
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard
0.52
13.0
High
27/19
35/24
Cooling
Overload
0.65
18.0
High
32/23
43/26
Low temperature
0.40
3.0
Low
21/15
21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)