FILE NO. SVM-02003
– 12 –
4-3. Outdoor Unit (RAS-13UAX)
4-4. Outdoor Unit (RAS-10UAX-T2, RAS-10UASX)
No.
Parts name
Type
Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
1
Compressor
PH160T2-4L2
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
2.43
3.78
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50/60Hz
2
Fan motor (for outdoor)
HF-240-30B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
245
388
3
Running capacitor
DS501155BPQA
AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371356CPNB
AC 370V, 35µF
(for compressor)
5
Overload relay
LAAO00A
U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
No.
Parts name
Type
Specifications
Output (Rated) 800W, 2poles, 1 phase, 220 – 240V, 50Hz
1
Compressor
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
2.159
3.899
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
3.88
5.06
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
2
Fan motor (for outdoor)
HF-240-30B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
245
388
3
Running capacitor
DS501155BPQA
AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371256CPNB
AC 370V, 25µF
(for compressor)
5
Overload relay
LPAP960B
U/T: 6.1A (80°C), OPEN: 135±5°C, CLOSE: 78±11°C
RM5510GNE94
(RAS-10UAX-T2)
PH102T1-4C
(RAS-10UASX)