background image

11

PLASMA ION

Capture ef

fi

 ciency of 

fl

 oating impurities in the air is accelerated by plasma ion 

contaminates such as bacteria, odor, smoke, dust and virus are caught and 
deactivated by Plasma lon.

1. When stopping operation.

 

After stopping, automatic cleaning starts 
(TIMER lamp turns on).
*  When operating time is 10 minutes 

or less, cleaning function does not operate.

2. When using together with the air conditioning

Air volume and direction setting of air conditioner have priority.

Operation

 

Operate Plasma lon while air conditioning.

Press the 

PURE

 button.

Stop

 

Stop both Plasma lon and air conditioning.

Press the 

 button.

 

Stop only Plasma lon.

Press the 

PURE

 button.

Note :

  Plasma lon operation does not remove harmful substances from 

cigarette smoke (carbon monoxide etc.). Open a window occasionally 
for ventilation.

PURE

or

For comfortable sleep, automatically control air 

fl

 ow and automatically turn OFF 

(Except in DRY mode).

1.  Press 

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

2.  Press 

 to cancel the comfort sleep operation.

Note

:   The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase). For heating 
operation, the set temperature will decrease.

COMFORT SLEEP OPERATION

12

HADA CARE FLOW
Air 

fl

 ow upward to the ceiling, provide Indirect air 

fl

 ow to body and homogenize 

room temperture.

HADA CARE FLOW operation

  

Press 

  For start and stop HADA CARE FLOW

Cancel

HADA CARE FLOW

HADA CARE FLOW

Note

:

 

During HADA CARE FLOW mode, FIX and SWING button cannot active

HADA CARE FLOW OPERATION

13

Power-Selection (

)

This function is used when the circuit breaker is shared with other electrical 
appliances. It limits the maximum current and power consumption to 100%, 75%, 
or 50% and can be implemented by POWER-SELECTION. The lower percentage, 
the higher saving and also longer compressor lifetime.

Note

:  

 

When the level is selected, POWER-SEL level 

fl

 ashes on remote LCD 

display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also 

fl

 ashes for 2 

seconds.

 

Due to the reason that POWER-SELECTION function limits the 
maximum current, inadequate cooling or heating capacity may occur.

Silent Operation (

)

Keep outdoor unit operating silently to ensure either yourself or neighborhood 
will have a tight sleep in nighttime. By this feature, the heating capacity will be 
optimized to deliver such silent experience. The silent operation can be selected 
from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2

Silent 1:

Though operating silently, the Heating (or Cooling) capacity is still prioritized to 
ensure having suf

fi

 cient comfort inside the room.

This setting is a perfect balance between the Heating (or Cooling) capacity and 
the Sound level of outdoor unit.

Silent 2:

Compromising the Heating (or Cooling) capacity to the Sound level in any 
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit by 
4 dB(A).

Note

:  

 

While activating of Silent operation, inadequate heating (or cooling) 
capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit)

POWER-SELECTION AND SILENT 
OPERATION (OUTDOOR UNIT)

14

[100%]

[75%]

[50%]

SILENT#2

SILENT#1

TIMER OPERATION

15

Set the timer when the air conditioner is operating.

Setting the ON Timer

Setting the OFF Timer

1

Press 

  : Set the desired ON 

timer.

Press 

  : Set the desired 

OFF timer.

2

Press 

  : Set the timer.

Press 

  : Set the timer.

3

Press 

  : Cancel the timer.

Press 

  : Cancel the timer.

Note:

 

Keep the remote control in accessible transmission to the indoor unit; 
otherwise, the time lag of up to 15 minutes will occur.

 

The setting will be saved for the next same operation.

PRESET OPERATION

16

Set your preferred operation for future use. The setting will be memorized by 
the unit for future operation (except air

fl

 ow direction).

1. Select your preferred operation.

2. Press and hold 

 for 3 seconds to memorize the setting.

The 

P

 mark displays.

3. Press 

 : Operate the preset operation.

Summary of Contents for RAS-07E2AVSG-A

Page 1: ...1122350219 OWNER S MANUAL R32 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit Outdoor unit RAS 07 10 13 16E2AVSG A RAS 07 10 13 16E2KVSG A ...

Page 2: ...m without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater In order to avoid fire explosion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the ...

Page 3: ...e used for a long time turn off the main switch or the circuit breaker It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual This appliance is not intended for use by person including children with reduced physical sensory o...

Page 4: ... Weekly timer ON OFF Temp for Weekly timer On timer button ON Set clock button CLOCK Check button CHECK Filter reset button FILTER Temperature button TEMP Swing louver button SWING Fan speed button FAN Set louver button FIX High power button Hi POWER Power selection Silent button P SEL SILENT Program P1 P4 Day Edit button Setup button SET Off timer button OFF Clear button CLR Reset button RESET EC...

Page 5: ...hes on remote LCD display for 3 seconds In case of 75 and 50 level number 75 or 50 also flashes for 2 seconds Due to the reason that POWER SELECTION function limits the maximum current inadequate cooling or heating capacity may occur Silent Operation Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime By this feature the heating capac...

Page 6: ...mmended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris 7 Some minor cracking sound may occur when unit operating This is normal because the cracking sound may be caused by expansion contraction of plastic Note Item 2 to 6...

Page 7: ...n incomplete setting is indicated if the TIMER lamp is blinking Press twice Notes 1 Place the remote control where the indoor unit can receive the signal This will increase the accuracy of the timing between the remote control and the air conditioning unit 2 The ON OFF timer can be set during the WEEKLY TIMER operation In this situation the air conditioner will first follow the normal timer until ...

Page 8: ...MEMO ...

Page 9: ...MEMO ...

Page 10: ...MEMO ...

Page 11: ......

Page 12: ...1122350219 ...

Reviews: