Tests and Diagnostics
(f)
Auto Power On
Use this option to set a time and date for automatic power on and enable or
disable the ring indicator feature.
Alarm Date Option
appears only when
Alarm Time
is enabled.
Set the parameters for the Auto Power On (automatic power on) function and
the Wake-up on LAN in the “OPTIONS” window. To set the time, use
Space
or
BackSpace
. Press
↓
to move the cursor to the right and
↑
to move the
cursor to the left when you set the date and time.
For the
Alarm Time
, set the time to turn on the power automatically. The
“second” cannot be set. When it is set to “Disabled”, the time to turn on
automatically is not set.
The
Wake-up on LAN
is a function to turn on the power automatically by the
call from the administrator. It can be set to “Enabled” only when “Built-in
LAN” is set to “Enabled”. To activate this function, use the AC adapter.
On Battery
The following settings can be changed when the Wake-up on LAN is Enabled.
Enabled
Wake-up on LAN function whenoperating from the battery.
Disabled
Wake-up on LAN function whenoperating from the battery
(Default).
NOTE:
1. Do not remove the AC adaptor and battery pack at the same time when you use this
feature. If you do so, data saved by the resume function will be lost. You must also
reset this option.
2. If you have set a password and the computer boots by the Auto Power On function and
Standby is on, the computer will start with the instant security function enabled. The
password = message is not displayed; however, you must enter the password to use the
computer.
3. This option is enabled only once, the setting is reset, after booting up.
Alarm Time
= Disabled
Wake-up on LAN
= Disabled
on Battery
= Disabled
Critical Battery Wake-up
=
Enabled
OPTIONS
3-90 [CONFIDENTIAL]
PORTEGE A600 Maintenance Manual (960-710)
Summary of Contents for Portege A600
Page 10: ...x CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 41: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 42: ...Troubleshooting Procedures 2 ii CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 2 ...
Page 46: ...Troubleshooting Procedures 2 vi CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 119: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 120: ...Tests and Diagnostics 3 ii CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 3 ...
Page 124: ...Tests and Diagnostics 3 vi CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 208: ...Tests and Diagnostics 3 84 CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 223: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 224: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ A600 Maintenance Manual 960 710 ...
Page 228: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ A600 Maintenance Manual 960 710 ...
Page 313: ... CONFIDENTIAL Appendices ...
Page 314: ...Appendices App ii CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 324: ...Appendices App xii CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 348: ...Appendices Appendix B Board Layout B 18 CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...
Page 406: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTEGE A600 Maintenance Manual 960 710 ...