– 244 –
Outdoor Unit
Pressure sensor characteristics
• Input/output wiring summary
Pin No.
High pressure side (Pd)
Low pressure side (Ps)
Input/output name
Lead wire color
Lead wire color
Input/output name
OUTPUT
—
GND
+5V
1
2
3
4
White
—
Black
Red
—
White
Black
Red
—
OUTPUT
GND
+5V
• Output voltage vs. pressure
Input/output name
Input/output name
0.5~4.3V
0~3.73MPa
0.5~3.5V
0~0.98MPa
Indoor Unit
Temperature sensor characteristics
0
4.41
5.1
0.5
4.3
5
0
0.98
1.47
5.1
0.5
3.5
5
3.73
High pressure-side output voltage (V)
Low pressure-side output voltage (V)
Pressure (MPa)
Pressure (MPa)
0
5
10
15
20
25
30
35
40
45
50
55
60
33.8
26.1
20.4
16.0
12.6
10.0
8.0
6.4
5.2
4.2
3.5
2.8
2.3
Temperature [
°
C]
Indoor TA(TSA), TRA,TF(TFA) sensor
Resistance
[k
Ω
]
Temperature [
°
C]
60
10
20
30
40
50
20
30
10
0
Resistance [k
Ω
]
AMP Air Conditioning
www.ampair.co.uk | [email protected]