No.
Part name
Heat
exchanger
Procedure
1) Perform work of item
.
2) Remove the pipe holder from the rear side
of the main unit.
3) Take off fixing screws (2 pcs.) at the left side
of the end plate of the heat exchanger.
4) Take off fixing screws (2 pcs.) at the right
side of the heat exchanger.
Remarks
Bearing base
Bearing
Drain pipe
Bearing
1) Perform works of items
,
-4), and
-
5),
and then remove bearing from the
bearing
base.
<Caution to reassembly>
In case of shooting-out of bearing part from the
housing, push into the specified position and
incorporate in the main unit.
Pipe holder
Fixing screws
Fixing screws
FILE NO. SVM-1
40
7
8