CUTTING A HOLE AND MOUNTING INSTALLATION PLATE
When the installation plate is directly mounted on the wall
65 mm
100 mm
The center of the pipe
hole is above the arrow.
Pipe
hole
Cutting a hole
In case of installing the refrigerant pipes from the rear:
1. Decide the hole position for piping at 100mm from
the arrow mark (
) on the installation plate and
drill a hole with Ø65mm at a slight downward slant
toward outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold
separately.
Mounting the installation plate
For installation of the indoor unit,
use the paper pattern in the accessory parts.
107
85
127.5
170
Mounting screw
Pipe hole
Pipe hole
Indoor unit
Thread
Weight
Hook
Hook
1
Installation
plate
Hook
5
CAUTION
Failure to firmly install the unit may result in personal injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type walls, make 5mm dia. holes in the wall.
• Insert clip anchors for appropriate
mounting screws.
NOTE
• Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it.
Projection
15mm or less
7
Mounting screw
Ø4 × 25
Clip anchor
(local parts)
5mm dia. hole
Anchor bolt
NO
GOOD
NO
GOOD
OK
1. Securely fit the installation plate onto the wall by screwing
it in the upper and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with
anchor bolts, utilize the anchor bolt holes as illustrated in
the above figure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a mounting
screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal
injury and property damage.