Check the addresses of the indoor units. (For details, see “Advanced control” in this manual.)
(Code: [12] for the system, [13] for indoor units, and [14] for groups)
Line
Indoor
Group
Line
Indoor
Group
Line
Indoor
Group
Line
Indoor
Group
Settings
Settings
Settings
Settings
Did you change the setting for changing the ventilation FAN speed?
If you did not, put a tick against “No change”. If you did, put a tick against the item you selected.
(For details, see “Advanced control” in this manual.)
Changing the ventilation FAN
speed
(Code: [EB])
Changing the ventilation FAN
speed
(Code: [EB])
Changing the ventilation FAN
speed
(Code: [EB])
Changing the ventilation FAN
speed
(Code: [EB])
No change
High
Low
Imbalance
[0002]
[0003]
[0004]
No change
High
Low
Imbalance
[0002]
[0003]
[0004]
No change
High
Low
Imbalance
[0002]
[0003]
[0004]
No change
High
Low
Imbalance
[0002]
[0003]
[0004]
* “High” may be “Extra High”.
Compatible with RBC-AMT32E
* “High” may be “Extra High”.
Compatible with RBC-AMT32E
* “High” may be “Extra High”.
Compatible with RBC-AMT32E
* “High” may be “Extra High”.
Compatible with RBC-AMT32E
Did you change the setting for changing the operation output?
If you did not, put a tick against “No change”. If you did, put a tick against the item you selected.
(For details, see “Advanced control” in this manual.)
Changing the operation output
(Code: [ED])
Changing the operation output
(Code: [ED])
Changing the operation output
(Code: [ED])
Changing the operation output
(Code: [ED])
No change
ON during
normal
operation
ON during
normal
operation
or the
nighttime
heat purge
operation
ON during
the
nighttime
heat purge
operation
ON when
the SA fan
is running
ON when
the EA fan
is running
[0000]
[0001]
[0002]
[0003]
[0004]
No change
ON during
normal
operation
ON during
normal
operation
or the
nighttime
heat purge
operation
ON during
the
nighttime
heat purge
operation
ON when
the SA fan
is running
ON when
the EA fan
is running
[0000]
[0001]
[0002]
[0003]
[0004]
No change
ON during
normal
operation
ON during
normal
operation
or the
nighttime
heat purge
operation
ON during
the
nighttime
heat purge
operation
ON when
the SA fan
is running
ON when
the EA fan
is running
[0000]
[0001]
[0002]
[0003]
[0004]
No change
ON during
normal
operation
ON during
normal
operation
or the
nighttime
heat purge
operation
ON during
the
nighttime
heat purge
operation
ON when
the SA fan
is running
ON when
the EA fan
is running
[0000]
[0001]
[0002]
[0003]
[0004]
Did you change the setting for changing the abnormal signal / bypass ventilation signal output?
If you did not, put a tick against “No change”. If you did, put a tick against the item you selected.
(For details, see “Advanced control” in this manual.)
Changing the abnormal signal /
bypass ventilation signal output
(Code: [EE])
Changing the abnormal signal /
bypass ventilation signal output
(Code: [EE])
Changing the abnormal signal /
bypass ventilation signal output
(Code: [EE])
Changing the abnormal signal /
bypass ventilation signal output
(Code: [EE])
No change
ON when an
abnormal
signal is
detected
ON when
the bypass
ventilation
signal is
detected
[0000]
[0001]
No change
ON when an
abnormal
signal is
detected
ON when
the bypass
ventilation
signal is
detected
[0000]
[0001]
No change
ON when an
abnormal
signal is
detected
ON when
the bypass
ventilation
signal is
detected
[0000]
[0001]
No change
ON when an
abnormal
signal is
detected
ON when
the bypass
ventilation
signal is
detected
[0000]
[0001]
165-EN
166-EN