– 37 –
Hydro Unit
Installation Manual
12
Technical parameters
Technical parameters for heat pump combination heater
Climate condition : average climate
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and
the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Models
Outdoor Unit
HWT-401HW-E
HWT-601HW-E
Hydro Unit
HWT-601F21SM3W-E
HWT-601F21ST6W-E
Air-to-Water Heat Pump
yes
yes
Water-to-water heat pump
no
no
Brine-to-water heat pump
no
no
Low-temperature heat pump
no
no
Equipped with a supplementary heater
no
no
Heat pump combination heater
yes
yes
Parameters for Low-temperature application/ Medium-temperature application
Medium
Medium
Symbol
Unit
Value
Item
Rated heat output (*)
P
rated
kW
5
6
Seasonal space heating energy
efficiency
η
s
%
135
132
Declared
capacity for
heating for
part load at
indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C
Pdh
kW
4.0
5.0
Tj = + 2 °C
Pdh
kW
2.5
3.4
Tj = + 7 °C
Pdh
kW
1.6
2.0
Tj = + 12 °C
Pdh
kW
1.5
1.5
Tj = bivalent
temperature
Pdh
kW
4.0
5.0
Tj = operation limit
temperature
Pdh
kW
3.5
4.5
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh
kW
-
-
Bivalent temperature
T
biv
°C
-7
-7
Cycling interval capacity for heating
P
cych
kW
-
-
Degradation co-efficient (**)
C
dh
-
0.8
0.8
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C
COPd
-
2.18
2.10
Tj = + 2 °C
COPd
-
3.48
3.22
Tj = + 7 °C
COPd
-
4.28
4.58
Tj = + 12 °C
COPd
-
6.35
6.35
Tj = bivalent
temperature
COPd
-
2.18
2.10
Tj = operation limit
temperature
COPd
-
1.83
1.81
Tj = - 15 °C
(if TOL < - 20 °C)
COPd
-
-
-
Operation limit temperature
TOL
°C
-10
-10
Cycling interval efficiency
P
cych
-
-
-
Heating water operating limit
temperature
WTOL
°C
55
55
Power
consumption in
modes other than
active mode
Off mode
P
OFF
kW
0.008
0.008
Thermostat-off mode
P
TO
kW
0.040
0.040
Standby mode
P
SB
kW
0.008
0.008
Crankcase heater mode
P
CK
kW
0.008
0.008
Supplementary
heater
Rated heat output (*)
P
sup
kW
5
6
Type of energy input
220-240V
~
, 50Hz
220-240V
~
, 50Hz
Other items
Capacity control
variable
variable
Sound power level, indoors/outdoors
L
WA
dB
42/65
42/65
Rated air flow rate, outdoors
-
m
3
/h
2015
2015
For heat pump
combination
heater
Declared load profile
-
-
L
L
Daily electricity consumption
Q
elec
kWh
3.627
3.627
Water heating energy efficiency
η
wh
%
136
136
Contact details
Toshiba Carrier Air-conditioning Europe Sp. z o.o. ul. Gda
ń
ska 131, 62-200 Gniezno, Poland
Technical parameters for heat pump combination heater
Climate condition : average climate
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and
the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Models
Outdoor Unit
HWT-801H (R)W-E
HWT-1101H (R)W-E
Hydro Unit
HWT-1101F21SM3W-E, HWT-1101F21MM3W-E
HWT-1101F21ST6W-E, HWT-1101F21MT6W-E
HWT-1101F21ST9W-E, HWT-1101F21MT9W-E
Air-to-Water Heat Pump
yes
yes
Water-to-water heat pump
no
no
Brine-to-water heat pump
no
no
Low-temperature heat pump
no
no
Equipped with a supplementary heater
no
no
Heat pump combination heater
yes
yes
Parameters for Low-temperature application/ Medium-temperature application
Medium
Medium
Symbol
Unit
Value
Item
Rated heat output (*)
P
rated
kW
8
8
Seasonal space heating energy
efficiency
η
s
%
142
142
Declared
capacity for
heating for
part load at
indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C
Pdh
kW
7.3
7.3
Tj = + 2 °C
Pdh
kW
4.6
4.5
Tj = + 7 °C
Pdh
kW
3.0
3.0
Tj = + 12 °C
Pdh
kW
2.3
2.3
Tj = bivalent
temperature
Pdh
kW
7.3
7.3
Tj = operation limit
temperature
Pdh
kW
6.7
6.7
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh
kW
-
-
Bivalent temperature
T
biv
°C
-7
-7
Cycling interval capacity for heating
P
cych
kW
-
-
Degradation co-efficient (**)
C
dh
-
0.9
0.9
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C
COPd
-
2.12
2.12
Tj = + 2 °C
COPd
-
3.60
3.58
Tj = + 7 °C
COPd
-
4.75
4.75
Tj = + 12 °C
COPd
-
7.00
7.00
Tj = bivalent
temperature
COPd
-
2.12
2.12
Tj = operation limit
temperature
COPd
-
1.90
1.89
Tj = - 15 °C
(if TOL < - 20 °C)
COPd
-
-
-
Operation limit temperature
TOL
°C
-10
-10
Cycling interval efficiency
P
cych
-
-
-
Heating water operating limit
temperature
WTOL
°C
65
65
Power
consumption in
modes other than
active mode
Off mode
P
OFF
kW
0.007
0.007
Thermostat-off mode
P
TO
kW
0.049
0.049
Standby mode
P
SB
kW
0.007
0.007
Crankcase heater mode
P
CK
kW
0.000
0.000
Supplementary
heater
Rated heat output (*)
P
sup
kW
8
8
Type of energy input
220-240V
~
, 50Hz
220-240V
~
, 50Hz
Other items
Capacity control
variable
variable
Sound power level, indoors/outdoors
L
WA
dB
42 (F21S), 44 (F21M) / 65 42 (F21S), 44 (F21M) / 65
Rated air flow rate, outdoors
-
m
3
/h
3142
3506
For heat pump
combination
heater
Declared load profile
-
-
XL
XL
Daily electricity consumption
Q
elec
kWh
6.110
6.110
Water heating energy efficiency
η
wh
%
130
130
Contact details
Toshiba Carrier Air-conditioning Europe Sp. z o.o. ul. Gda
ń
ska 131, 62-200 Gniezno, Poland
73-EN
74-EN
Summary of Contents for HWT-1101F21MM3W-E