Hydro Unit

Owner’s Manual

4

User maintenance

Periodic maintenance (once a year) is necessary for this product. Consult the installation company.
If a problem occurs, contact the installation company or dealer.

5

Air to Water Heat Pump operations and 

performance

3 minutes protection function

3-minutes protection function prevents the air to water heat pump from starting for initial 3 minutes after the main 
power switch/circuit breaker is turned on for re-starting the air to water heat pump.

Power failure

Power failure during operation will stop the unit completely.
• To restart the operation, we should mention Auto restart function.

Heating characteristics

Defrosting operation

If the outdoor unit is frosted during the heating or hot water supply operation, defrosting starts automatically (for 
approximately 2 to 10 minutes) to maintain the heating capacity.
• During the defrosting operation, the defrosted water will be drained from the bottom plate of the outdoor unit.

Heating capacity

In the heating operation, the heat is absorbed from the outside and brought into the room. This way of heating is 
called heat pump system. When the outside temperature is too low, it is recommended to use another heating 
apparatus in combination with the air to water heat pump.

Attention to snowfall and freeze on the outdoor unit

• In snowy areas, the air intake and air discharge of the outdoor unit are often covered with snow or frozen up.

If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming.

• In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for 

freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or 
poor warming.

Air to water heat pump operating conditions

For proper performance, operate the air to water heat pump under the following temperature conditions:

If air to water heat pump is used outside of the above conditions, safety protection may work.

Cooling operation

Outdoor temperature

: 10°C to 43°C

Room temperature

: 18°C to 32°C (Dry bulb temp.)

Hot water

Outdoor temperature

: –20°C to 43°C

Room temperature

: 5°C to 32°C

Heating operation

Outdoor temperature

: –20°C to 25°C

Room temperature

: 5°C to 32°C

12-EN

Summary of Contents for HWS-1404XWHM3-E

Page 1: ...AIR TO WATER HEAT PUMP Hydro Unit Model name HWS 804XWHM3 E HWS 804XWHT6 E HWS 804XWHT9 E HWS 1404XWHM3 E HWS 1404XWHT6 E HWS 1404XWHT9 E Owner s Manual English ...

Page 2: ...e read this owner s manual carefully before using the system Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual before handing it over to the Customer ADOPTION OF NEW REFRIGERANT This Air to Water Heat Pump is a new type which adopts a new refrigerant HFC R410A instead of...

Page 3: ...here is a suspected problem with the operation of the Air to Water Heat Pump continuous operation is not recommended operational failures may lead to machine breakdown electric shock a fire etc Do not spill water or other liquid onto the Hydro Unit If the unit is wet it could cause an electric shock Warnings at movement and repair Do not attempt to move or repair the unit yourself Due to the prese...

Page 4: ...instructions Failure to do so may cause malfunction break down or water to leak from the unit Clear away snow before it accumulates on the outdoor unit Accumulated snow can lead to malfunction and damage Do not locate other electric appliances or furniture underneath the unit Water may drip from the unit which could lead to rust unit failure and damage to property Do not allow the obstruction of a...

Page 5: ...eration setting 7 STEP button Specifies switching STEP number in a day for weekly schedule 8 TEST button Used for test run or service 9 FROST PROTECTION button Controls minimum operation for unused period going out absence etc for anti freezing 10 NIGHT button Controls the night set back operation 11 AUTO TEMP button Switches setting temperature automatically according to outside temperature Press...

Page 6: ...er heater is energised during hot water operation Lights when heating is selected Lights during hot water supply operation Lights when cooling is selected Lights while hot water boost is activated Lights when the FROST PROTECTION button is pressed and goes out when the button is pressed again Lights when the ANTI BACTERIA button is pressed and goes out when the button is pressed again Lights when ...

Page 7: ...am is set Lights during time setting and scheduled operation setting 21 Indication Description Lights while internal pump pump 1 or expansion pump pump 2 is driven Lights when the auxiliary boiler or external booster heater supports the heat pump operation Lights when the unit enters the data set mode and goes out when the unit exits the data set mode Lights when the unit enters the service mode a...

Page 8: ...n Performing heating or cooling operation Press the ZONE1 2 button to start heating or cooling operation The set temperature appears under on the remote controller When ZONE2 is provided the set temperature appears simultaneously under During the heat pump operation or while the internal heater or backup heater is energized is displayed Use the OPERATE MODE button to select cooling operation or he...

Page 9: ...5 4 3 2 1 0 1 2 3 4 or 5 Only ZONE1 temperature is displayed When the SET button is pressed after the temperature is changed the set temperature is registered When the TEST button is pressed the registered data is determined The unit exits the function code setting mode and A appears on the display Each time AUTO TEMP button is pressed the mode changes as follows Hot water Performing hot water sup...

Page 10: ...st protection is operated with schedule timer on it may stop during its operation Setting the end days and time for the frost protection operation Press the FROST PROTECTION button for 4 seconds or more while the frost protection operation is enabled is displayed on the remote controller to enter the setting mode The setting mode is indicated on the remote controller Select the code number to be s...

Page 11: ...ek Example Monday Tuesday to Saturday Same as Monday Sunday Setting the schedule function Press the SCHEDULE button and press the SET button within five seconds while the mark is blinking The mark changes to lighting and the schedule function starts working Cancelling the schedule function Press the SCHEDULE button and press the CL button within five seconds while the mark is blinking The mark dis...

Page 12: ...et is displayed 4 Set temperature Set the temperature for ZONE1 or ZONE2 with the SELECT button and TEMP buttons Press the SELECT button so that the mark lights for the zone to be changed Enter setting temperature with the TEMP buttons 5 Set operation mode Set the operation mode heating or cooling with the OPERATE MODE button 6 Determine the settings Press the SET button to determine the settings ...

Page 13: ...rbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air to water heat pump Attention to snowfall and freeze on the outdoor unit In snowy areas the air intake and air discharge of the outdoor unit are often covered with snow or frozen up If sn...

Page 14: ...0 16 0 11 2 14 0 16 0 Input kW 2 34 3 16 3 72 2 34 3 16 3 72 COP 4 80 4 44 4 30 4 80 4 44 4 30 Cooling Capacity kW 10 0 11 0 13 0 10 0 11 0 13 0 Input kW 3 26 3 81 4 80 3 26 3 81 4 80 EER 3 07 2 89 2 71 3 07 2 89 2 71 Refrigerant R410A Dimension HxWxD mm 1 340x900x320 Cord heater W 75 Hydro Unit HWS 804XWHM3 E HWS 804XWHT6 E HWS 804XWHT9 E Back up heater capacity 3 0 6 0 9 0 Power supply for back ...

Page 15: ...itch turned on Time indication is blinking Date time setting is not made Set date and time An error code is displayed on the remote controller Contact the installation company Room is not cooled or heated Is scheduled operation set Check whether scheduled operation is set Is night setback operation set Check the setting on the remote controller Is the air to water heat pump operating in Auto mode ...

Page 16: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: