GX9 ASD Quick Start Guide
33
Monitor Mode
The
Monitor
mode allows the user to monitor motor performance variables, control settings, and
configuration data during motor operation. The items are listed and described below.
Note:
The
Monitor
mode is a read-only mode. The settings cannot be changed from the
Monitor
mode. For information on how to change the values, see the section titled
Default Setting Changes on pg. 53
.
Note:
Any two of the Underlined monitored items may be selected for display at the
Frequency Command
screen while running via Program
Utilities
.
Note:
The
F701
setting will determine if the
Current
and
Voltage
values displayed
appear as
A
(Amps) and
V
(Voltage), or if the value is shown as a
%
(percentage)
of the ASD rating.
Frequency at Trip
—
Displays the at-trip frequency.
Frequency Reference
— Displays the
Frequency Setpoint
.
Output Current
— Displays the
Output Current
as a percentage of the rated capacity of the
GX9 ASD.
DC Bus Voltage
— Displays the
Bus Voltage
as a percentage of the rated capacity of the
GX9 ASD.
Output Voltage
— Displays the
Output Voltage
as a percentage of the rated capacity of the
GX9 ASD.
AM Output
— Displays the
AM
output terminal value for the function assigned to the
AM
terminal.
FM Output
—
Displays the
FM
output terminal value for the function assigned to the
FM
terminal.
Motor OL (Overload) Trip
—
Displays the
Motor Overload
Trip
value as a percentage of the
rated capacity of the motor.
Motor Load
— Displays the real-time
Motor Load
as a percentage of the rated capacity of the
motor.
ASD OL (Overload) Trip
—
Displays the
ASD Overload
Trip
value as a percentage of the rated
capacity of the ASD.
ASD Load
— Displays the
ASD Load
as a percentage of the rated capacity of the GX9 ASD.
Run Time
— Displays the
Cumulative Run Time
in hours.
Compensation Frequency
— Displays the
Output Frequency
after the application of the slip
compensation correction value (Post Compensation Frequency).
DBR OL (Overload) Trip
— Displays the
DBR Overload
Trip
value as a percentage of the
Dynamic Braking Resistor
capacity.
DBR Load
— Displays the
DBR Load
as a percentage of the
Dynamic Braking Resistor
capacity.
Feedback (Inst)
— Provides a status of the
Real-Time Feedback
in Hz.
Feedback (1 Second)
— Provides a status of the
1-Second Averaging
feedback in Hz.
Torque
—
Displays the
Output Torque
as a percentage of the rated capacity of the GX9 ASD.
Torque Reference
—
Displays the
Torque Reference
as a percentage of the maximum torque
available.
onitored
ems
Summary of Contents for GX9 ASD
Page 1: ...GX9 ASD Quick Start Guide TOSHIBA GX9 ASD Quick Start Guide DN 66900 001 March 2014 ...
Page 2: ......
Page 3: ...Document Number 66900 001 March 2014 GX9 ASD Quick Start Guide ...
Page 4: ......
Page 88: ...78 GX9 ASD Quick Start Guide Figure 33 GX9 ASD 5 0 20 HP Enclosure ...
Page 89: ...GX9 ASD Quick Start Guide 79 Figure 34 GX9 ASD 25 75 HP Enclosure ...
Page 90: ...80 GX9 ASD Quick Start Guide Figure 35 GX9 ASD 100 200 HP Enclosure ...
Page 91: ...GX9 ASD Quick Start Guide 81 Figure 36 GX9 ASD 250 400 HP Enclosure ...
Page 92: ...82 GX9 ASD Quick Start Guide Figure 37 GX9 ASD 500 800 HP Enclosure ...
Page 93: ...GX9 ASD Quick Start Guide 83 Figure 38 GX9 ASD 900 1200 HP Enclosure ...
Page 99: ......