Note:
The event that caused the Trip(s) must be corrected or must decrease to less than the threshold
value required to cause the trip to allow for a Reset to be recognized. In the event of multiple
active trips, the trip displayed will remain until all faults are corrected and all trips are cleared.
Dynamic Braking Resistor Overcurrent
• Unsupported DBR configuration attempt.
• ASD inability to discharge the bus voltage during regeneration.
• No dynamic braking resistor (DBR) installed.
• Deceleration time is too short.
• Improper DBR setup information.
• Defective IGBT7 (or IGBT7 circuit).
• 3-phase input voltage is above specification.
Dynamic Braking Resistor Overload
• Unsupported DBR configuration attempt.
• Deceleration time is too short.
• DBR setting adjustment required.
• Overvoltage Stall setting adjustment required.
Earth Fault
• Ground fault at the motor.
• Ground fault at the output of the ASD.
• Current leakage to
Earth Ground
.
EEPROM Data Fault
• EEPROM read malfunction.
EEPROM Fault
• EEPROM write malfunction.
Emergency Off
• Emergency Off command received via EOI or remotely.
Encoder Loss
• Encoder signal missing while running during closed-loop operation.
Flash Memory Fault
• Flash memory malfunction.
Gate Array Fault
• Defective Gate Array or Gate Array malfunction.
Input Phase Loss
• 3-phase input to the ASD is low or missing.
Load Drooping
• Load requirement is in excess of the capabilities of the motor.
Load End Short Circuit
• Improper wiring at the ASD output to the motor.
Low Current
• Improper Low Current detection level setting.
Main Board EEPROM Fault
• Internal EEPROM malfunction.
Motor Overload
• V/f setting needs to be adjusted.
• Motor is locked.
• Continuous operation at low speed.
• Load requirement exceeds ability of the motor.
• Startup frequency setting adjustment required.
No Fault
• No active faults.
Option Fault
• Optional device malfunction.
• Improper system settings (at ASD or optional device).
• Loose or improper connection.
Fault Screen Display
Possible Causes
Summary of Contents for GX7R ASD
Page 1: ...GX7R ASD Quick Start Guide TOSHIBA GX7R ASD Quick Start Guide DN 68986 002 September 2014 ...
Page 2: ...GX7R ASD Quick Start Guide DN 68986 002 September 2014 ...
Page 76: ...68 GX7R ASD Quick Start Guide Figure 23 480 Volt 30 100 HP GX7R ASD ...
Page 77: ...GX7R ASD Quick Start Guide 69 Figure 24 480 Volt 125 150 HP GX7R ASD ...