GX7R ASD Quick Start Guide
65
Trip Monitor from ASD
The
Trip Monitor From ASD
function records the trip name of up to four trips and catalogs each trip as
Most Recent
,
Second Most Recent
,
Third Most Recent
, and
Fourth Most Recent
. Once reset (Clear
Trip), the trip records are erased. If no trips have occurred since the last reset,
No Fault
is displayed for
each trip record.
Note:
An improper ASD setup may cause some trips — reset the ASD to the
Factory Default
settings before pursuing a systemic malfunction (Program
Utility Parameters
Type Reset
Restore Factory Defaults).
Trip Record at Monitor Screen
The at-trip condition of the last incurred trip may be viewed at the
Monitor
screen (see
). The
Monitor
screen at-trip record is erased when the ASD is reset and may be viewed without the use of the
RTC option.
Clearing a Trip
Once the cause of the trip has been corrected, performing a
Reset
re-enables the ASD for normal
operation.
The record of a trip may also be cleared using either of the following methods:
• Cycling power (trip info may be saved via
F602
if desired),
• Pressing the
Stop
|
Reset
key twice,
• Remotely via the communications channel,
• Momentarily connecting terminal
RES
to
CC
of the
Control Terminal Strip
, or
• Via Program
Utility Parameters
Type Reset
Clear Trip
(clears Trip Monitor From ASD).
Summary of Contents for GX7R ASD
Page 1: ...GX7R ASD Quick Start Guide TOSHIBA GX7R ASD Quick Start Guide DN 68986 002 September 2014 ...
Page 2: ...GX7R ASD Quick Start Guide DN 68986 002 September 2014 ...
Page 76: ...68 GX7R ASD Quick Start Guide Figure 23 480 Volt 30 100 HP GX7R ASD ...
Page 77: ...GX7R ASD Quick Start Guide 69 Figure 24 480 Volt 125 150 HP GX7R ASD ...